Kyoritsu 2413R is A genuine RMS AC clamp meter, gifted of measuring leakage current that is very productive for the work point. Comprising late postscript broad 68mm transformer jaws, the 2413R provides the expertise to clamp going concerning for all three or four wires (3 phases) together for a quantity leakage current measurement.
The Kyoritsu 2413R is competent of measuring AC current going on to 1000A across five scales (200mA/2/20/200A/1000A). The tester features a frequency selector switch to eliminate the effect of harmonics, providing more accurate measurement, especially at the low halt of the current scale. The 2413R is then meant to minimize the effects of uncovered stray magnetic fields, increasing the correctness of the tester.
Featuring a 0.1mA final, the 2413R clamp tester provides accurate current readings. The Kyoritsu 2413R furthermore provides a two-mannerism analog output terminal, integrating the completion to partner occurring to a recorder. The 2413R incorporates a backlit screen for chemical analysis in low open conditions. Standard Kyoritsu features such as the data-accord play in and top-bond conflict a role are in addition to include.
Key Features: Kyoritsu KEW 2413R Clamp Meters
• Large transformer jaws of 68mm diameter make it possible to clamp on all three or four wires (3 phases) together for leakage current measurement.
• True RMS enables accurate measurement of distorted waveforms.
• The measurement from mA up to AC 1000A
• Frequency filter switch to eliminate the effect of the harmonics.
• 2-way analog output terminal
• Resolution 0.1mA
Specifications: Kyoritsu KEW 2413R Clamp Meters
| AC A (50/60Hz) |
200mA/2/20/200/1000A ±2.5%rdg±5dgt (200mA/2/20A) ±3.0%rdg±5dgt (200A, 0 - 500A) ±5.5%rdg (501 - 1000A) |
| AC A (WIDE) |
200mA/2/20/200/1000A ±1.8%rdg±5dgt (50/60Hz) (200mA/2/20A) ±2.0%rdg±5dgt (50/60Hz) (200A, 0 - 500A) ±5.0%rdg (50/60Hz) (501 - 1000A) |
| Crest factor |
3.0 or less |
| Conductor size |
Ø68mm max. |
| Frequency response |
40Hz - 1kHz |
| Output |
Waveform : AC200mV against the maximum value of each range (1000A range is 100mV) Recorder : DC200mV against the maximum value of each range (1000A range is 100mV) |
| Applicable standards |
IEC 61010-1 CAT III 300V Pollution degree 2 IEC 61010-2-032 |
| Power source |
6F22 (9V) × 1 *Continuous measuring time: Approx. 60 hours |
| Dimensions |
250(L) × 130(W) × 50(D)mm |
| Weight |
Approx. 570g (including battery) |
| Included Accessories |
9094 (Carrying Case) 6F22 × 1 Instruction Manual |
| Optional Accessories |
7073 (2WAY Output Cord) |