Model: Fluke 771 Milliamp Process Clamp Meter
The character of Fluke 771 Milliamp Process Clamp Meter is Features a detachable clamp with an extension cable for measurements in tight locations. This product creates a place in the market because this is working with the best and it's rugged accurate and reliable all the people.Yes
The Fluke 771 delivers altogether the basics. It events 4-20 mA signals without "breaking the loop", allowing you to pretend low-level dc current even though saving downtime and money. You can use it to play a portion output signals from transmitters without breaking the loop along furthermore maintaining and troubleshooting process and automation equipment.
This saves era and avoids disruption to the process. For more convenience, the detachable clamp can be attached to the wire you vis-a-vis psychoanalysis while you involve the meter associated with the augmentation cable to a greater than before viewing slope. This Fluke is especially satisfying in addition to taking readings in tight locations.
The Fluke 771 Milliamp Process Clamp Meter is available now at Tools Bangladesh. Loop calibrator that measures 4 to 20 mA signals without breaking the loop so it can be your right choice for your best work.
Key features: Fluke 771 Milliamp Process Clamp Meter
- Loop calibrator that measures 4 to 20 mA signals without breaking the loop
- Features best in class 0.2% accuracy
- Delivers 0.01 mA resolution and sensitivity
- Measures mA signals for PLC and control system analog I/O
- Features a detachable clamp with extension cable for measurements in tight locations
Specifications: Fluke 771 Milliamp Process Clamp Meter
| Specifications |
| Diameter of measurable conductor |
0.177 in or 4.5 mm max |
| Operating temperature |
-10 to 50°C |
| Storage temperature |
-25 to 60°C |
| Operating humidity |
< 90% @ < 30°C, < 75% @ 30 to 55°C |
| Operating altitude |
0 to 2000 m |
| IP rating |
IP 40 |
| Size |
59 x 38 x 212 mm (2.32 x 1.5 x 8.35 in) |
| Weight |
260 G, (9.1 oz) |
| Vibration |
Random 2 g, 5 to 500 Hz |
| Shock |
1 m drop test (except the jaw) |
| EMI/RFI |
Meets EN61326-1 |
For current measurement w/ JAW, add 1 mA to
specification for EMC field strengths of 1 V/m up to 3 V/m. |
| Temperature coefficient |
0.01% °C
(< 18°C or > 28°C) |
| Power, battery life |
(2) AA 1.5 V Alkaline, IEC LR6, 40 hours typical |
| Warranty |
Three years for electronics
One year for cable and clamp assembly |
| Functional Specifications |
mA measurement
(measured by clamp) |
Resolution / range |
0 to 20.99 mA |
| Accuracy |
0.2% + 2 counts |
| Resolution / range |
21.0mA to 100.0 mA |
| Accuracy |
1% + 5 counts |
Includes: Fluke 771 Milliamp Process Clamp Meter
- Soft Carrying Case
- Users Manual
Resources: Fluke 771 Milliamp Process Clamp Meter
Manuals (3)
771 | Instruction sheet
771 | Instruction sheet supplement
771 | Calibration manual
Register products
Register product
Write a Review
Simple to use and very practical for troubleshooting process control systems. The readings are reliable, and the compact design makes it easy to carry around on the job