Amprobe ACD-41PQ 1000A Power Quality Clamp Meter True-rms sensing measures active (W), reactive (VAR) and apparent (VA) power with dual-display power factor readout and also it's working accurately that are rugged reliable and trusted.
The Amprobe ACD-40 provides an easily reached and in goings-on habit to post if the electrical system is affected by harmonics.
Add on the order of troubleshooting capabilities taking into account the ACD-40PQ data-logging feature or get a bond of unconditional knack analysis following the ACD-41PQ. Increase measuring efficiency taking into consideration an optional PC interface kit.
THD-F is defined as (Total Harmonic RMS / Fundamental RMS) x 100%
However, if you buy this product you can keep trust on Iconic Engineering, I think never be loose.
Key Features: Amprobe ACD-41PQ 1000A Power Quality Clamp Meter with Temperature
- True-rms sensing measures active (W), reactive (VAR) and apparent (VA) power with dual-display power factor readout
- Total harmonics distortion (THD), AC/DC voltage up to 600V, AC current up to 1000A, resistance, frequency, temperature
- Peak hold
- Optional PC interface capability (RS-232 KIT2)
- Audible continuity
- Auto power off
- Automatic polarity
- Low battery indication
- Data hold
- Large, easy to read LCD display with backlight
- Accommodates conductors up to 1.77 (45mm) in diameter
- Carrying case, test leads, batteries (installed), thermocouple and manual included
- Voltage overload protection for all functions up to 600V AC/DC
Specifications: Amprobe ACD-41PQ 1000A Power Quality Clamp Meter with Temperature
| FEATURE |
ACD-41PQ |
ACD-45PQ |
| True-rms |
• |
| AC Current |
40.00 A, 400.0 A, 1000 A |
40.00 A, 400.0 A, 600 A |
| AC/DC Voltage |
600.0 V |
| Resistance |
999.9 Ω |
| Continuity |
• |
| Temperature |
-58 °F → 572 °F (-50 °C → 300 °C) |
– |
| Frequency |
5.00 Hz → 500.0 Hz |
| Active power |
(W) 0 kW → 600.0 kW |
0 kW → 360.0 kW |
| Reactive power (VAR) |
0 kVAR → 600.0 kVAR |
0 kVAR → 360.0 kVAR |
| Apparent power (VA) |
0 kVA → 600.0 kVA |
0 kVA → 360.0 kVA |
| Power Factor |
0.10 → 0.99 |
| Energy (KWHr) |
• |
• |
| Total Harmonic Distortion (THD%) |
0.0 % → 99 % |
– |
| Accommodates Conductors |
up to 1.77″ (45 mm) in diameter |
up to 1.02″ (26 mm) in diameter |
| Specifications |
| TRMS: |
YES |
| AC Current: |
40.0 / 400.0 / 1000 A |
| AC Current Basic Accuracy: |
+/-(1.0% Rdg + 5 LSD) @ 50 and 60Hz |
| DC Voltage: |
600.0V |
| DC Voltage Basic Accuracy: |
+/-(0.5% Rdg + 5 LSD) |
| AC Voltage: |
600.0V |
| AC Voltage Basic Accuracy: |
+/-(0.5% Rdg + 5 LSD) @ 50 / 60 Hz |
| Resistance: |
999.9O |
| Resistance Basic Accuracy: |
+/-(1.0% Rdg + 6 LSD) |
| Frequency: |
5.00Hz to 500.0Hz |
| Frequency Basic Accuracy: |
+/-(0.5% Rdg +4 LSD) |
| THD-F *: |
0.0% to 99.9% |
| THD-F * Basic Accuracy**: |
1.5% of Reading + 6d @ Fund Frequency |
| Active Power (W): |
0 to 600.0 kW |
| Active Power (W) Basic Accuracy: |
+/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th PF > 0.7 |
| Reactive Power (VAR): |
0 to 600.0 kVAR |
| Reactive Power (VAR) Basic Accuracy: |
+/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th PF > 0.7 |
| Apparent Power (VA): |
0 to 600.0 kVA |
| Apparent Power (VA) Basic Accuracy: |
+/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th |
| Power Factor: |
0.10 to 0.99 |
| Power Factor Basic Accuracy: |
+/- 3 LSD @ Harmonics Fund to 21th |
| Temperature: |
-58°F to 572° F (-50° C to 300° C) |
| Temperature Basic Accuracy: |
+/-(2.0% Rdg + 6°F) +/-(2.0 % Rdg + 3°C) |
For complete specs please download the product datasheet under the “Resources” tab.
Includes: Amprobe ACD-41PQ 1000A Power Quality Clamp Meter with Temperature
- TRMS sensing measures Active (W), Reactive (VAR) and Apparent (VA) Power with dual-display Power Factor readout
- Total Harmonics Distortion THD, AC/DC Voltage up to 600V
- AC Current up to 1000A, Resistance, Frequency, Temperature
Accessories: Amprobe ACD-41PQ 1000A Power Quality Clamp Meter with Temperature
- Carrying case,
- Test leads,
- Batteries (installed),
- Type-K thermocouple