Specifications |
DC Volts ranges: |
200 mV, 2 V, 20 V, 200 V, 600 V, Accuracy: ± (1.0 % rdg + 1 dgt) |
AC Volts (45 Hz to 500 Hz) ranges: |
200 mV, 2 V, 20 V, 200 V, 600 V, Accuracy: ± (1.5 % rdg + 5 dgts) |
Voltage resolution: |
100 µV |
Voltage input impedance: |
10 MΩ |
Overload protection: |
200 mV: 600 V dc or 600 V ac rms (3 minutes) All other ranges: 600 V dc or 600 V ac rms |
DC Current ranges: |
200 µA, 2 mA, 20 mA, 200 mA, Accuracy: ± (1.5 % rdg + 1 dgt) |
AC Current (45 Hz to 500 Hz) ranges: |
200 µA, 2 mA, 20 mA, 200 mA, Accuracy: ± (2.0 % rdg + 5 dgts) |
Current resolution: |
0.1 µA |
Input protection: |
315 mA/1000 V fast blow ceramic fuse 6.3 mm x 32 mm on mA input |
Burden voltage: |
300 mV max. (1 V max. on 200 mA range) |
Resistance: |
200 Ω , 2 kΩ , 20 kΩ , 200 kΩ
Accuracy: ± (1.0 % rdg + 4 dgts) |
Resistance: |
2 MΩ
Accuracy: ± (1.5 % rdg + 4 dgts) |
Resistance: |
20 MΩ
Accuracy: ± (2.0 % rdg + 5 dgts) |
Resistance resolution: |
100 mΩ |
Open circuit voltage: |
0.3 V dc typical, (3.0 V dc on 200 Ω range) |
Overload protection: |
600 V dc or 600 V ac rms |
Continuity: audible indication: |
75 Ω ± 25 Ω, Response Time: 100 ms |
Diode test current: |
1.0 mA (approximate) ±(1.5 % rdg + 3 dgts) |
Diode test resolution: |
1 mV |
Open circuit voltage: |
3.0 V dc typical |
Non-ontact voltage indicator: |
Sense voltage 70 V to 600 V ac; beeper chirps and bright red LED on, works on all ranges |
Battery test: |
1.5 V, 9 V Accuracy: ± (3.5 % rdg + 2 dgts) |