| Specifications |
| DC Voltage ranges: |
1000 mV, 10 V, 100 V, 1000 V |
| DC Voltage accuracy: |
all ranges ± (0.25 % rdg + 5 dgt) |
| DC Voltage resolution: |
100 µV |
| AC Voltage (45 Hz to 2 kHz) True-rms ranges: |
1000 mV, 10 V, 100 V, 750 V |
| AC Voltage (45 Hz to 2 kHz) True-rms accuracy: |
750 V range: 45 to 1 kHz: ± (2.0 % rdg + 10 dgts) |
| AC Voltage (45 Hz to 2 kHz) True-rms accuracy: |
All other ranges, 45 to 500 Hz: ± (1.2 % rdg + 10 dgts) |
| AC Voltage (45 Hz to 2 kHz) True-rms accuracy: |
All other ranges, 500 to 2 kHz: ± (2.0 % rdg + 10 dgts) |
| AC coupled: |
True RMS specified from 5 % to 100 % of range |
| AC + DC Voltage (45 Hz to 2 kHz): |
1000 mV, 10 V, 100 V, 750 V |
| DC Current ranges: |
100 µA, 1000 µA, 10 mA, 100 mA, 400 mA, 10 A |
| DC Current accuracy: |
100 µA range: ± (0.5 % rdg + 10 dgt) |
| DC Current accuracy: |
1000 uA to 400 mA ranges: ± (0.5 % rdg + 5 dgts) |
| DC Current accuracy: |
10 A range: ± (1.5 % rdg + 10 dgt) |
| DC Current resolution: |
0.01 µA |
| AC Current (True-rms) ( AC + DC) (45 Hz – 1kHz) ranges: |
100 µA, 1000 µA, 10 mA, 100 mA, 400 mA, 10 A |
| AC Current (True-rms) ( AC + DC) (45 Hz – 1kHz) accuracy: |
100 µA to 100 mA ranges: ± (1.5 % rdg + 10 dgts) |
| AC Current (True-rms) ( AC + DC) (45 Hz – 1kHz) accuracy: |
400 mA range: ± (2.0 % rdg + 10 dgts) |
| AC Current (True-rms) ( AC + DC) (45 Hz – 1kHz) accuracy: |
10 A range: ± (2.5 % rdg + 10 dgts) |
| AC Current (45 Hz to 1 kHz) True-rms resolution: |
0.01 µA |
| Resistance ranges: |
1000 O 10 kO 100 kO 1000 kO 10 MO 40 MO |
| Resistance accuracy: |
1000 O to 1000 kO ranges: ± (0.5 % rdg + 8 dgts) |
| Resistance accuracy: |
10 MO range: ± (1.0 % rdg + 10 dgts) |
| Resistance accuracy: |
40 MO range: ± (2.0 % rdg + 10 dgts) |