Model: Testo 350 Flue Gas Analyzer

Testo 350 Flue Gas Analyzer Ideal for professional exhaust gas analysis and industrial emission measurements and that provides the rugged and reliable results to test point.

The Testo 350 exhaust gas analyzer is a rugged piece of kit designed to meet the demands of a variety of different measuring and analysis applications. It is also excellently suited for complex data compilation.

Always the Testo product that you will get from Tools Bangladesh. Order from here if you need it and get the facility for delivery anywhere in Bangladesh for free.

Key Features: Testo 350 Flue Gas Analyzer

  • Increased measurement range for unlimited measurements even when gas concentrations are higher
  • Easy-to-change gas sensors and easy access to wearing parts
  • Sealed housing with built-in impact protection for use in harsh conditions
  • Easy operation of the analyzer unit via Control Unit or easy mission software (both products available separately)

Specifications: Testo 350 Flue Gas Analyzer

Temperature - NTC

Measuring range

-20 to +50 °C

Accuracy

±0.2 °C (-10 to +50 °C)

Resolution

0.1 °C (-20 to +50 °C)

Ambient temperature probe

Temperature - TC Type K (NiCr-Ni)

Measuring range

-200 to +1370 °C

Accuracy

±0.4 °C (-100 to +200 °C)

±1 °C (-200 to -100.1 °C)

±1 °C (200.1 to +1370 °C)

Resolution

0.1 °C (-200 to +1370 °C)

Temperature - TC Type S (Pt10Rh-Pt)

Measuring range

0 to +1760 °C

Accuracy

±1 °C (0 to +1760 °C)

Resolution

0.1 °C (0 to +1760 °C)

Differential Pressure - Piezoresistive

Measuring range

-40 to +40 hPa

-200 to +200 hPa

Accuracy

±1.5 % of mv (-40 to -3 hPa)

±1.5 % of mv (+3 to +40 hPa)

±0.03 hPa (-2.99 to +2.99 hPa)

±1.5 % of mv (-200 to -50 hPa)

±1.5 % of mv (+50 to +200 hPa)

±0.5 hPa (-49.9 to +49.9 hPa)

Resolution

0.01 hPa (-40 to +40 hPa)

0.1 hPa (-200 to +200 hPa)

Absolute Pressure

Measuring range

600 to +1150 hPa

Accuracy

±10 hPa

Resolution

1 hPa

Flue gas O₂

Measuring range

0 to +25 Vol.%

Accuracy

±0.8% of fsv (0 to +25 Vol.%)

Resolution

0.01 Vol.% (0 to +25 Vol.%)

Reaction time t₉₀

20 s (t₉₅)

Flue gas CO (with H₂-compensation)

Measuring range

0 to +10000 ppm

Accuracy

±5 % of mv (+200 to +2000 ppm)

±10 % of mv (+2001 to +10000 ppm)

±10 ppm (0 to +199 ppm)

Resolution

1 ppm (0 to +10000 ppm)

Reaction time t₉₀

40 s

H₂ only as an indicator

Flue gas COlow

Measuring range

0 to 500 ppm

Accuracy

±5 % of mv (+40 to +500 ppm)

±2 ppm (0 to +39.9 ppm)

Resolution

0.1 ppm (0 to +500 ppm)

Reaction time t₉₀

40 s

H₂ only as an indicator

Flue gas NO

Measuring range

0 to +4000 ppm

Accuracy

±5 % of mv (+100 to +1999 ppm)

±10 % of mv (+2000 to +4000 ppm)

±5 ppm (0 to +99 ppm)

Resolution

1 ppm (0 to +4000 ppm)

Reaction time t₉₀

30 s

Flue gas Nolow

Measuring range

0 to +300 ppm

Accuracy

±5 % of mv (+40 to +300 ppm)

±2 ppm (0 to +39.9 ppm)

Resolution

±0.1 ppm (0 to +300 ppm)

Reaction time t₉₀

30 s

Flue gas NO₂

Measuring range

0 to +500 ppm

Accuracy

±5 % of mv (+100 to +500 ppm)

±5 ppm (0 to +99.9 ppm)

Resolution

0.1 ppm (0 to +500 ppm)

Reaction time t₉₀

40 s

Flue gas SO₂

Measuring range

0 to +5000 ppm

Accuracy

±5 % of mv (+100 to +2000 ppm)

±10 % of mv (+2001 to +5000 ppm)

±5 ppm (0 to +99 ppm)

Resolution

1 ppm (0 to +5000 ppm)

Reaction time t₉₀

30 s

Flue gas degree of effectivity, Eta (calculated)

Measuring range

0 to +120 %

Resolution

0.1 % (0 to +120 %)

Flue gas loss (calculated)

Measuring range

0 to +99.9 %

Resolution

0.1 % (0 to +99.9 %)

Flue gas dewpoint (calculated)

Measuring range

0 to +99.9 °Ctd

Resolution

0.1 °Ctd (0 to +99.9 °Ctd)

Flue gas CO₂ calculation (calculated from O₂)

Measuring range

0 to CO₂ max

Accuracy

calculated from O₂ ±0.2 Vol.%

Resolution

0.01 Vol.%

Flue gas H₂S

Measuring range

0 to +300 ppm

Accuracy

±5 % of mv (+40 to +300 ppm)

±2 ppm (0 to +39.9 ppm)

Resolution

0.1 ppm (0 to +300 ppm)

Reaction time t₉₀

35 s

Flue gas CO₂ - NDIR

Measuring range

0 to +50 Vol.%

Accuracy

±0.3 Vol.% + 1 % of mv (0 to 25 Vol.%)

±0.5 Vol.% + 1.5 % of mv (>25 to 50 Vol.%)

Resolution

0.01 Vol.% (0 to 25 Vol.%)

0.1 Vol.% (> 25 Vol.%)

Reaction time t₉₀

10 s

Velocity / Volume flow

Measuring range

0 to +40 m/s

Resolution

0.1 m/s (0 to +40 m/s)

Methane (CH₄)

Measuring range

100 to 40000 ppm

Accuracy

< 400 ppm (100 to 4000 ppm)

< 10 % of mv (> 4000 ppm)

Resolution

10 ppm

Min. O₂ requirement in flue gas

2 % + (2 x mV methane)

Reaction time t₉₀

< 40 s

Response factor

1

Lower explosion limit (LEL) must be adhered to. 
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.

Propane (C₃H₈)

Measuring range

100 to 21000 ppm

Accuracy

< 400 ppm (100 to 4000 ppm)

< 10 % of mv (> 4000 ppm)

Resolution

10 ppm

Min. O₂ requirement in flue gas

2 % + (5 x mV propane)

Reaction time t₉₀

< 40 s

Response factor

1.5

Lower explosion limit (LEL) must be adhered to. 
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.

Butane (C₄H₁₀)

Measuring range

100 to 18000 ppm

Accuracy

< 400 ppm (100 to 4000 ppm)

< 10 % of mv (> 4000 ppm)

Resolution

10 ppm

Min. O₂ requirement in flue gas

2 % + (6.5 x mV butane)

Reaction time t₉₀

< 40 s

Response factor

2

Lower explosion limit (LEL) must be adhered to. 
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.

General technical data

Weight

4800 g

Dimensions

330 x 128 x 438 mm

Operating temperature

-5 to +45 °C

Product-/housing material

ABS

Protection class

IP40

Product colour

Black

Connectable probes

1 x combustion air temperature probe; 1 x flue gas probe; 1 x temperature probe; 1 x differential pressure

Battery type

lithium batteries

Battery life

5 h

Power supply

AC mains unit 100V to 240V (50 to 60 Hz)

DC electric tension input

11V to 40V

Dewpoint calculation

0 °Ctd; 99 °Ctd

Max. dust load

20 g/m³ dust in flue gas

Max. neg. press./flue gas

-300 mbar

Includes: Testo 350 Flue Gas Analyzer

  • Testo 350 Flue Gas Analyzer

 

Accessories: Testo 350 Flue Gas Analyzer

  • Testo easy mission software
  • Spare thermal paper for the printer, permanent
  • Testo fast printer IRDA
  • Transport case
seller

Sellers

Connect your real buyer on Tools Bangaldesh where visit the maximum customer for Tools In Bangladesh.

e-marketplace

e-Marketplace

Tools Bangladesh is a Trustworthy e-Marketplace in Bangladesh. Connect buyer and seller on the trade fair.

growth

Buyers

Get the reliable and authentic Tools at the best price in Bangladesh with on time delivery entire Bangladesh.