Testo 340 Flue gas analyzer for use in industry is the rugged reliable and very productive product. Testo 340 Flue gas analyzer for use in industry is the testo 340 flue gas analyzer gives you professional technology, easy handling and practical be responsive in one instrument. The high-sham testo 340 flue gas analyzer is fitted subsequent to an O2 sensor and can be equipped when occurring to 3 accumulation sensors.
Key Features: Testo 340 Flue gas analyzer for use in industry
-
Can measure CO, COlow, NO, low, NO2 or SO2
-
Extended measuring range for use in environments with high gas concentrations
-
Precalibrated gas sensors for quick and easy sensor change
-
Integrated pressure difference and air flow measurements for mass flow calculations
Specifications: Testo 340 Flue gas analyzer for use in industry
| Differential Pressure - Piezoresistive |
|
Measuring range
|
-200 to 200 hPa
|
|
Accuracy
|
±0.5 hPa (-49.9 to 49.9 hPa)
±1.5 % of mv (Remaining Range)
|
|
Resolution
|
0.1 hPa
|
| Absolute Pressure |
|
Measuring range
|
+600 to +1150 hPa
|
|
Accuracy
|
±10 hPa
|
|
Resolution
|
1 hPa
|
| Flue gas O₂ |
|
Measuring range
|
0 to 25 Vol.%
|
|
Accuracy
|
±0.2 Vol.%
|
|
Resolution
|
0.01 Vol.%
|
|
Reaction time t₉₀
|
< 20 s
|
| Flue gas CO (with H₂-compensation) |
|
Measuring range
|
0 to 10000 ppm
|
|
Accuracy
|
±10 ppm or ±10 % of mv (0 to 200 ppm)
±20 ppm or ±5 % of mv (201 to 2000 ppm)
±10 % of mv (2001 to 10000 ppm)
|
|
Resolution
|
1 ppm
|
|
Reaction time t₉₀
|
< 40 s
|
| Flue gas COlow |
|
Measuring range
|
0 to 500 ppm
|
|
Accuracy
|
±2 ppm (0 to 39.9 ppm)
±5 % of mv (Remaining Range) data corresponds to 20°C ambient temperature. Additional temperature coefficient 0.25% of reading/K.
|
|
Resolution
|
0.1 ppm
|
|
Reaction time t₉₀
|
< 40 s
|
| Flue gas NO |
|
Measuring range
|
0 to 4000 ppm
|
|
Accuracy
|
±5 ppm (0 to 99 ppm)
±5 % of mv (100 to 1999 ppm)
±10 % of mv (2000 to 4000 ppm)
|
|
Resolution
|
1 ppm
|
|
Reaction time t₉₀
|
< 30 s
|
| Flue gas Nolow |
|
Measuring range
|
0 to 300 ppm
|
|
Accuracy
|
±2 ppm (0 to 39.9 ppm)
±5 % of mv (Remaining Range)
|
|
Resolution
|
0.1 ppm
|
|
Reaction time t₉₀
|
< 30 s
|
| Flue gas NO₂ |
|
Measuring range
|
0 to 500 ppm
|
|
Accuracy
|
±10 ppm (0 to 199 ppm)
±5 % of mv (Remaining Range)
|
|
Resolution
|
0.1 ppm
|
|
Reaction time t₉₀
|
< 40 s
|
| Flue gas SO₂ |
|
Measuring range
|
0 to 5000 ppm
|
|
Accuracy
|
±10 ppm (0 to 99 ppm)
±10 % of mv (Remaining Range)
|
|
Resolution
|
1 ppm
|
|
Reaction time t₉₀
|
< 40 s
|
| Differential Pressure flue gas Draught - Piezoresistive |
|
Measuring range
|
-40 to +40 hPa
|
|
Accuracy
|
±0.03 hPa (-2.99 to +2.99 hPa)
±1.5 % of mv (Remaining Range)
|
|
Resolution
|
0.01 hPa
|
| Temperature |
|
Measuring range
|
-40 to +1200 °C
|
|
Accuracy
|
±0.5 °C (0 to +99 °C)
±0.5 % of mv (Remaining Range)
|
|
Resolution
|
0.1 °C
|
| Flue gas degree of effectivity, Eta (calculated) |
|
Measuring range
|
0 to 120 %
|
|
Resolution
|
0.1 %
|
| Flue gas loss (calculated) |
|
Measuring range
|
0 to 99.9 %
|
|
Resolution
|
0.1 %
|
| Flue gas dewpoint (calculated) |
|
Measuring range
|
0 to 99.9 °Ctd
|
|
Resolution
|
0.1 °Ctd
|