The Hioki DT4200 Digital Multimeter Series consists of a complete lineup of 9 models, ranging from professional to industrial to pocket types. The DT4282 is a high-precision 60,000 count digital multimeter with direct 10A input and all of the functions and features required for advanced testing in laboratories and R&D. CAT IV 600 V, CAT III 1000 V. HIOKI DIGITAL MULTIMETER DT4282 Price in Bangladesh offers accurate and reliable measurement for professionals and hobbyists. Discover competitive pricing, excellent features, and durability. Ideal for electrical testing and troubleshooting, this multimeter combines precision with ease of use. Get the best value for your investment today.
Key Features
- 60000 count, 5-digit display, high-resolution measurements
- ±0.025% DC V basic accuracy, wide 20 Hz to 100 kHz AC V frequency characteristics
- Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
- Terminal shutter mechanism (prevents erroneous test lead insertion)
- Measure up to 10 A with direct input (DT4282 only)
- Dual display lets you check voltage and frequency simultaneously
Basic specifications
Accuracy guaranteed: 1 year
Regarding DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information.
| DC Voltage range |
60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. |
| AC Voltage(*1) range |
60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz
Basic accuracy 45 - 65 Hz : ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3) |
| DC + AC Voltage(*1) range |
6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHz
Basic accuracy 45 - 65 Hz : ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3) |
| Resistance range |
60.000 Ω to 600.0 MΩ, 8 ranges, (Conductance: 600.00 nS, DT4282 only)
Basic accuracy: ±0.03 % rdg. ±2 dgt. |
| DC Current range |
600.00 μA to 10.000 A, 6 ranges, Basic accuracy: ±0.05 % rdg. ±5 dgt. |
| AC Current(*1) range |
600.00 μA to 10.000 A, 6 ranges,
Basic accuracy 45 - 65 Hz : ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3)
Frequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range) |
AC Current(*1) range
(use with Clamp on probes) |
N/A |
| Peak |
DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated)
AC V, DC/AC A measurement:
Signal width 1 msec or more (single), 250 μsec or more (repeated) |
| Capacitance range |
1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt. |
| Continuity Check |
Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more |
| Diode test |
Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages |
| Frequency range |
AC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio)
99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.005 % rdg. ±3 dgt. |
| dB conversion |
Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stages
Display dB conversion value of AC voltage (dBV) |
Temperature
(thermocouples) |
K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F)
Add accuracy of the Thermocouple probe to main unit accuracy: ±0.5 % rdg. ±3 °C |
| Other functions |
Filter function (remove harmonic noise, use only at 600 V AC, 1000 V AC ranges), display value hold, auto hold, MAX/MIN value display, PEAK value display, relative value display, sampling setting, internal memory (400 data), auto-power save, USB communication (option), mis-insertion prevention shutters, decibel conversion, 4-20 mA percentage conversion |
| Display |
Main and Sub displays: 5-digits LCD, max. 60000 digits |
| Display refresh rates |
5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s ) |
| Power supply |
LR6 (AA) alkaline batteries ×4, Continuous use: 100 hours |
| Dimensions and mass |
93 mm (3.66 in) W × 197 mm (7.76 in) H× 53 mm (2.09 in) D, 650 g (22.9 oz) (with test leads holder and batteries) |
| Included accessories |
Test Lead L9207-10(*2) ×1, Instruction Manual ×1, LR6 Alkaline Battery ×4 |
- (*1)Zero-suppression: For small inputs below the guarantee range, zero is effectively displayed.
- (*2)Replaced by the probe L9300 starting with batches manufactured in March, 2025.
| Included accessories |
Test Lead L9207-10(*2) ×1, Instruction Manual ×1, LR6 Alkaline Battery ×4 |
| Included accessories |
Test Lead L9207-10(*2) ×1, Instruction Manual ×1, LR6 Alkaline Battery ×4 |