The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The DT4255 is a digital multimeter designed for maximum safety with voltage measurement terminals that are protected by a fuse. Safety CAT IV 600 V, CAT III 1000 V.
HIOKI DIGITAL MULTIMETER DT4255 Price in Bangladesh offers accurate and reliable measurement for professionals and technicians. Known for its durability and advanced features, this multimeter ensures precise voltage, current, and resistance readings. Ideal for electrical testing and troubleshooting, the DT4255 combines ease of use with high performance. Get the best HIOKI DIGITAL MULTIMETER DT4255 Price in Bangladesh with fast delivery and genuine warranty from trusted sellers.
Key Features
- Prevents short-circuit accidents with a fast-blow fuse and current-limiting resistor (DT4255)
- Prevents accidents with clamp-on sensor-based current measurement (DT4254, DT4255)
- Voltage detection function (DT4254, DT4255)
- Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
- Broad -25°C to 65°C (-13°F to 149°F) operating temperature range (DT4254, DT4255)
- Dual display lets you check voltage and frequency simultaneously
Basic specifications
Accuracy guaranteed: 1 year
Regarding DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information.
| DC Voltage range |
600.0 mV to 1000 V
5 ranges, Basic accuracy: ±0.3 % rdg. ±3 dgt. |
| AC Voltage range |
6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz
Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
| AUTO AC/DCV |
Yes |
| Resistance range |
600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±3 dgt. |
| DC Current range |
N/A |
| From 4 to 20mA Percentage conversion display |
N/A |
AC Current range
(use with Clamp on probes) |
10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 - 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
Temperature
(thermocouples) |
N/A |
| Voltage detection |
Hi: AC40 V to 600 V, Lo: AC80 V to 600 V |
| Capacitance range |
1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt. |
| Frequency range |
99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage),
Basic accuracy: ±0.1 % rdg. ±1 dgt. |
| Continuity check |
Continuity threshold [ON]: 25 Ω or less ,
[OFF]: 245 Ω or more,
Response time: 0.5 ms or more |
| Diode test |
Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less,
Threshold of forward voltage: 0.15 V to 1.5 V |
| Other functions |
Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option) |
| Display |
Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph |
| Display refresh rates |
5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s) |
| Power supply |
LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF) |
| Dimensions and mass |
84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D,
390 g (13.8 oz) (including batteries and holster) |
| Included accessories |
Test lead L9207-10* ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4
* Replaced by the probe L9300 starting with batches manufactured in March, 2025. |
| Included accessories |
Test lead L9207-10* ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4
* Replaced by the probe L9300 starting with batches manufactured in March, 2025. |
| Included accessories |
Test lead L9207-10* ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4
* Replaced by the probe L9300 starting with batches manufactured in March, 2025. |