Fluke PS410 Patient Simulator
The PS410 is a compact high-performance simulator for patient monitor testing. This handheld device simulates a full range of cardiac rhythms and a wide variety of ECG conditions. It includes pacemaker simulation, 35 arrhythmia selections, and adult and pediatric normal-sinus rhythms. Small enough to fit in a pocket, the handy PS410 weighs less than a pound and is easy to operate. Technicians simply connect the simulator to the device under test and use the PS410 keypad to enter the code presets. The simulator then transmits the selected preset simulations to the device.
• Handheld
• 12-lead ECG simulation
• 12 arrhythmia selections
• Universal ECG jacks
• Auto sequencing of performance waveforms
• Battery operated
• PS410/DPM1B Bundle kit with custom carrying case for quick ECG/NIBP patient monitor testing
Specifications
ECG Simulation
-
Normal Sinus Rhythm: 12-lead with independent outputs referenced to RL.
-
Selectable Rates: 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, and 300 BPM.
-
Accuracy: ±1%.
-
Output Impedance: 940 Ω between leads.
-
ECG Amplitudes: 0.5, 1, and 2 mV.
-
Amplitude Accuracy: ±2% (Lead II).
-
High-Level Output: 1000x Lead II.
-
Waveforms: Square wave (2 Hz, 0.125 Hz), Pulse (30, 60, 120 BPM; 60 ms pulse width), Sine waves (0.5, 5, 10, 40, 50, 60 Hz at 1 mV amplitude), Triangle wave (2 Hz).
-
ST Segment Analysis: Elevated or depressed from -0.6 mV to 6 mV in 0.2 mV steps.
Arrhythmia Selections
-
Pacemaker Rhythms: Pacer non-capture, Pacer non-function, Demand pacer with occasional or frequent sinus, A-V sequential.
-
Artifacts: 50 Hz, 60 Hz, Muscle, Baseline, Respiration.
-
PVCs: Left and right ventricular focus, early, R on T, bigeminy, trigeminy, multi-focal, frequent multi-focal.
-
Ventricular Rhythms: PVCs at various rates, Ventricular tachycardia, Ventricular fibrillation (full and 1/2 size).
-
Supraventricular Rhythms: Supraventricular tachycardia, Premature atrial/nodal contraction, Asystole, Missed beat, Nodal rhythm, Irregular rhythm.
-
Atrial Rhythms: Atrial flutter, Atrial fibrillation (full and 1/2 size), Atrial tachycardia.
-
Heart Blocks: First-degree, Second-degree, Third-degree.
-
Bundle Branch Blocks: Right and Left bundle-branch block.
Pacemaker Simulation
-
Modes: Demand pacer with occasional or frequent sinus, A-V sequential.
-
Artifacts: 50 Hz, 60 Hz, Muscle, Baseline, Respiration.
General Specifications
-
Display: 2-line LCD.
-
Controls: 6 control keys; ON/OFF power switch.
-
Power: 9V battery or battery eliminator.
-
Housing: ABS plastic case.
-
Dimensions: 11.3 cm L x 7 cm W x 3.4 cm H (6.1 in L x 3.7 in W x 1.3 in H).
-
Weight: 0.4 kg (0.9 lb).
-
Operating Temperature: 15 °C to 35 °C (59 °F to 95 °F).
-
Storage Temperature: 0 °C to 50 °C (32 °F to 122 °F).
Optional Accessories
-
17024: Universal Banana Adapter.
-
17191: Carrying Case, single pocket.
-
17192: Carrying Case, double pocket.