Fluke IDA-5 Infusion Pump Analyzer
Ensure infusion pumps are tested accurately and quickly with the IDA-5 Infusion Device Analyzer. The IDA-5 is based on sophisticated measurement technology trusted by biomedical professionals around the world for over 20 years. The IDA-5 is a full-featured device that measures instantaneous flow, average flow, occlusion pressure, and dual flow based on IEC60601-2-24.
• Tests up to four infusion pumps at the same time
• Customizable test templates for quick and standardized testing
• On-board and PC-based automation • Compatible with virtually any type of infusion device
• Real-time snapshots of flow and pressure for immediate issue recognition
• Instantaneous and average flow measurement of up to 1500 ml/hr
• Occlusion pressure measurements to 45 psi • Single-flow, dual-flow (piggyback) and PCA testing
• Auto-start mode enables unit to begin testing only when fluid is detected to maximize accuracy
• Ability to automatically end flow measurement based on user-defined time, volume, or both
• Convenient and easy data entry with plug ’n play, USB-compatible keyboard or barcode scanner
• Built-in memory to save test results for printing or downloading to a computer
• Optional Ansur automation software completely integrates medical device testing, including electrical safety, visual inspection, and other performance parameters for total digital data management.
• Global support network delivering prompt service worldwide
Technical Specifications
Flow Rate Measurement
-
Range: 0.1 ml/h to 1500 ml/h (up to 2500 ml/h displayed)
-
Accuracy: 1% of reading ±1 Least Significant Digit (LSD) for flows of 16 to 200 ml/h with volumes over 20 ml; otherwise, 2% of reading ±1 LSD for volumes over 10 ml under laboratory conditions.
-
Maximum Test Duration: 100 hours
Volume Measurement
-
Range: 0.06 ml to 9999 ml
-
Accuracy: 1% of reading ±1 LSD for flow rates of 16 ml/h to 200 ml/h with volumes over 20 ml; otherwise, 2% of reading ±1 LSD for volumes over 10 ml under laboratory conditions.
-
Maximum Test Duration: 100 hours
PCA Bolus/Dual Flow Measurement
-
Minimum Bolus Volume: 0.5 ml
-
Resolution: 60 μl increments
-
Maximum Test Duration: 100 hours
Pressure Measurement
-
Method: Direct measurement at the inlet port
-
Range: 0 psi to 45 psi (equivalent to 0 to 310 kPa, 0 to 3.1 bar, or 0 to 3400 mmHg)
-
Accuracy: 1% of Full Scale ±1 LSD under laboratory conditions
-
Maximum Test Duration: 1 hour
General Specifications
-
Operating Voltage: 100 V ac to 240 V ac
-
Supply Frequency: 50/60 Hz
-
Power Consumption: <50 VA
-
Fuses: 20 mm T1.6 A H 250 V x 2
-
Dimensions (HxWxD): 30 cm x 20 cm x 20 cm (12 in x 8 in x 8 in)
-
Weight: 3.4 kg (approx.)
Software and Accessories
-
HydroGraph™ Graphics Software: Visualize and analyze test data with real-time graphs.
-
Ansur Automation Software: Integrates medical device testing, including electrical safety and visual inspection, for total digital data management.
-
Plug-and-Play Compatibility: Supports barcode scanners, keyboards, and printers for convenient data entry.