Product overview: 5615 Secondary Reference PRT

The 5615-12 (formerly Hart Scientific) is a Platinum Resistance Thermometer (PRT) with an Inconel™ 600 sheath that’s 305 mm (12 in) long and 6.35 mm (0.250 in) in diameter. It is a secondary reference temperature standard designed to bridge the gap between the highest laboratory standards and industrial or second-tier lab locations. It has accuracy of ± 0.012 °C at 0.01 °C.

The element is constructed of reference-grade platinum wire (99.999 % pure) for excellent stability. The wire is wound in a coil and placed in a mandrel where it’s uniformly supported in a manner that virtually eliminates hysteresis. The electrical configuration is a four-wire current-potential hookup that eliminate the effects of lead-wire resistance.

These Inconel™-sheathed probes have a fully supported sensing element, making them more durable than SPRTs. The element is protected in an ultrahigh-purity ceramic case with a hermetic glass seal to improve output stability by locking out moisture and contaminants.

This probe comes calibrated with ITS-90 coefficients, making it compatible with many excellent readout devices, including Fluke Calibration’s 1529 Chub-E4, 1560 Black Stack, and 1502A Tweener. It bridges the gap between a 100-ohm industrial RTD and an SPRT.

For those needing faster thermal response, or where diameter and immersion depth are problems, order the 5615-9 or 5615-6. These probes are excellent reference probes for comparison calibrations in a Fluke Calibration dry-well. The sheaths of the 5615-6 and 5615-9 are 4.76 mm (0.188 in) in diameter.

A printout of sensor resistance is provided in 1 °C increments for each probe. The 5615-9 and 5615-12 are calibrated from –196 °C to 420 °C. The 5615-6 is calibrated to 300 °C.

We’ve tested many of the probes on the market. We’ve used them in our manufacturing facility and tested them in the lab, and this is an excellent secondary standards PRT. Other instruments on the market are priced much higher, have lower stability, or are of lower quality.

Key Features

  • Inconel™ 600 sheath that’s 305 mm (12 in) long and 6.35 mm (0.250 in) in diameter
  • Calibrated accuracy of ± 0.012 °C at 0 °C.
  • Reference-grade platinum sensing element.
  • NVLAP-accredited calibration, lab code 200706-0.
  • Durable sensors, ideal in the factory, field, or lab.

Specifications: 5615 Secondary Reference PRT

Specifications
Temperature range
 
5615-12 and 5615-9: –200 °C to 420 °C
5615-6: –200 °C to 300 °C
Nominal resistance at 0 °C 100 Ω ± 0.10 Ω
Temperature coefficient 0.0039250 Ω/Ω/°C
Accuracy[1]
 
 
± 0.024 °C at –200 °C
± 0.012 °C at 0 °C
± 0.035 °C at 420 °CC
Short-term repeatability[2] ± 0.009 °C at 0.010 °C
Drift[3] ± 0.007 °C at 0.010 °C
Sensor length 28 mm (1.1 in)
Sensor location 6.9 mm ± 3.3 mm from tip (0.27 in ± 0.13 in)
Sheath dimensions 5615-6: 152 mm x 4.76 mm (6.0 in x 0.188 in)
5615-9: 229 mm x 4.76 mm (9.0 in x 0.188 in)
5615-12: 305 mm x 6.35 mm (12.0 in x 0.250 in)
Sheath diameter tolerance ± 0.127 mm (± 0.005 in)
Sheath material Inconel™ 600
Minimum insulation resistance 1000 MΩ at 23 °C
Transition junction temperature range[4] –50 °C to 200 °C
 
Transition junction dimensions 71 mm x 13 mm dia (2.8 in x 0.5 in)
Maximum immersion length
 
 
5615-6: 102 mm (4 in)
5615-9: 178 mm (7 in)
5615-12: 254 mm (10 in)
Response time[5] 9 seconds typical
Self heating (in 0 °C bath) 50 mW/°C
Lead-wire cable type PTFE insulated with PTFE jacket, 22 AWG
Lead-wire length 183 cm (72 in or 6 ft)
Lead-wire temperature range –50 °C to 200 °C
Calibration
 
 
NVLAP-accredited calibration included, lab code 200706-0. Please see calibration uncertainty table and its explanation of changeable uncertainties.
[1] Includes calibration and 100 hr drift (k=2)

[2] Three thermal cycles from min to max temp, includes hysteresis, 95 % confidence (k=2)

[3] After 100 hrs at max temp, 95 % confidence (k=2)

[4] Temperatures outside this range will cause irreparable damage. For best performance, transition junction should not be too hot to touch.

[5] Per ASTM E 644
NVLAP† Calibration Uncertainty
Temperature Expanded Uncertainty (k=2)
–196 °C 0.024 °C
–38 °C 0.011 °C
0 °C 0.010 °C
200 °C 0.018 °C
420 °C‡ 0.029 °C

Note: Calibration uncertainties depend on the uncertainties of the lab performing the calibration. Subsequent calibrations of this probe performed with different processes, at different facilities, or with changed uncertainty statements may state different uncertainties. †Lab code 200706-0 ‡5615-6 excluded

N/A

N/A

Product overview: 5615 Secondary Reference PRT

The 5615-12 (formerly Hart Scientific) is a Platinum Resistance Thermometer (PRT) with an Inconel™ 600 sheath that’s 305 mm (12 in) long and 6.35 mm (0.250 in) in diameter. It is a secondary reference temperature standard designed to bridge the gap between the highest laboratory standards and industrial or second-tier lab locations. It has accuracy of ± 0.012 °C at 0.01 °C.

The element is constructed of reference-grade platinum wire (99.999 % pure) for excellent stability. The wire is wound in a coil and placed in a mandrel where it’s uniformly supported in a manner that virtually eliminates hysteresis. The electrical configuration is a four-wire current-potential hookup that eliminate the effects of lead-wire resistance.

These Inconel™-sheathed probes have a fully supported sensing element, making them more durable than SPRTs. The element is protected in an ultrahigh-purity ceramic case with a hermetic glass seal to improve output stability by locking out moisture and contaminants.

This probe comes calibrated with ITS-90 coefficients, making it compatible with many excellent readout devices, including Fluke Calibration’s 1529 Chub-E4, 1560 Black Stack, and 1502A Tweener. It bridges the gap between a 100-ohm industrial RTD and an SPRT.

For those needing faster thermal response, or where diameter and immersion depth are problems, order the 5615-9 or 5615-6. These probes are excellent reference probes for comparison calibrations in a Fluke Calibration dry-well. The sheaths of the 5615-6 and 5615-9 are 4.76 mm (0.188 in) in diameter.

A printout of sensor resistance is provided in 1 °C increments for each probe. The 5615-9 and 5615-12 are calibrated from –196 °C to 420 °C. The 5615-6 is calibrated to 300 °C.

We’ve tested many of the probes on the market. We’ve used them in our manufacturing facility and tested them in the lab, and this is an excellent secondary standards PRT. Other instruments on the market are priced much higher, have lower stability, or are of lower quality.

Key Features

  • Inconel™ 600 sheath that’s 305 mm (12 in) long and 6.35 mm (0.250 in) in diameter
  • Calibrated accuracy of ± 0.012 °C at 0 °C.
  • Reference-grade platinum sensing element.
  • NVLAP-accredited calibration, lab code 200706-0.
  • Durable sensors, ideal in the factory, field, or lab.

Specifications: 5615 Secondary Reference PRT

Specifications
Temperature range
 
5615-12 and 5615-9: –200 °C to 420 °C
5615-6: –200 °C to 300 °C
Nominal resistance at 0 °C 100 Ω ± 0.10 Ω
Temperature coefficient 0.0039250 Ω/Ω/°C
Accuracy[1]
 
 
± 0.024 °C at –200 °C
± 0.012 °C at 0 °C
± 0.035 °C at 420 °CC
Short-term repeatability[2] ± 0.009 °C at 0.010 °C
Drift[3] ± 0.007 °C at 0.010 °C
Sensor length 28 mm (1.1 in)
Sensor location 6.9 mm ± 3.3 mm from tip (0.27 in ± 0.13 in)
Sheath dimensions 5615-6: 152 mm x 4.76 mm (6.0 in x 0.188 in)
5615-9: 229 mm x 4.76 mm (9.0 in x 0.188 in)
5615-12: 305 mm x 6.35 mm (12.0 in x 0.250 in)
Sheath diameter tolerance ± 0.127 mm (± 0.005 in)
Sheath material Inconel™ 600
Minimum insulation resistance 1000 MΩ at 23 °C
Transition junction temperature range[4] –50 °C to 200 °C
 
Transition junction dimensions 71 mm x 13 mm dia (2.8 in x 0.5 in)
Maximum immersion length
 
 
5615-6: 102 mm (4 in)
5615-9: 178 mm (7 in)
5615-12: 254 mm (10 in)
Response time[5] 9 seconds typical
Self heating (in 0 °C bath) 50 mW/°C
Lead-wire cable type PTFE insulated with PTFE jacket, 22 AWG
Lead-wire length 183 cm (72 in or 6 ft)
Lead-wire temperature range –50 °C to 200 °C
Calibration
 
 
NVLAP-accredited calibration included, lab code 200706-0. Please see calibration uncertainty table and its explanation of changeable uncertainties.
[1] Includes calibration and 100 hr drift (k=2)

[2] Three thermal cycles from min to max temp, includes hysteresis, 95 % confidence (k=2)

[3] After 100 hrs at max temp, 95 % confidence (k=2)

[4] Temperatures outside this range will cause irreparable damage. For best performance, transition junction should not be too hot to touch.

[5] Per ASTM E 644
NVLAP† Calibration Uncertainty
Temperature Expanded Uncertainty (k=2)
–196 °C 0.024 °C
–38 °C 0.011 °C
0 °C 0.010 °C
200 °C 0.018 °C
420 °C‡ 0.029 °C

Note: Calibration uncertainties depend on the uncertainties of the lab performing the calibration. Subsequent calibrations of this probe performed with different processes, at different facilities, or with changed uncertainty statements may state different uncertainties. †Lab code 200706-0 ‡5615-6 excluded

N/A

N/A

seller

Sellers

Connect your real buyer on Tools Bangaldesh where visit the maximum customer for Tools In Bangladesh.

e-marketplace

e-Marketplace

Tools Bangladesh is a Trustworthy e-Marketplace in Bangladesh. Connect buyer and seller on the trade fair.

growth

Buyers

Get the reliable and authentic Tools at the best price in Bangladesh with on time delivery entire Bangladesh.