Amprobe AMP-25 Mini-Clamp Features True-RMS sensing for accurate voltage measurements in noisy electrical environments Also it's giving Measures AC/DC current to 300 A (10mA resolution) that are rugged and reliable.
Small size doesn't desire little features. The Amprobe AMP-25 Mini-Clamp is pocket-sized, enabling sudden and easy spot checks of electrical systems.
With its rugged construction and CAT III 600V rating, the AMP-25 is a must-have professional troubleshooting tool for commercial electricians and electrical contractors.
The AMP-25 is designed to do something AC/DC load current and inrush current for motors. Essential features taking into account True-RMS, non-gate voltage and low p.s. filter make this clamp stand high adjoining clamps twice its size. With the AMP-25, you never have to sacrifice play a role for size.
Iconic Engineering has a store for suppling all over in Bangladesh. You can buy from here with the facility free shipping anywhere in Bangladesh.
Key Features: Amprobe AMP-25 Mini-Clamp
- Features True-RMS sensing for accurate voltage measurements in noisy electrical environments
- Measures AC/DC current to 300 A (10mA resolution)
- Includes a low pass filter to accurately measure voltage and current on variable frequency drives
- Inrush current for motor start-up monitoring
- Non-contact voltage detection (NCV) for detecting presence of voltage
- Jaw opening to 1 in (25 mm)
- Autoranging
- DCA zero and data hold
- Maximizes battery life with auto power off
- Backlit display for easy measurement viewing in bright and dim environment
- CAT III 600 V safety rated
Specifications: Amprobe AMP-25 Mini-Clamp
| Feature |
AMP-25 |
Best Accuracy |
| AC Current(1) |
60.00 / 300.0 A |
+/-(1.5% + 5 LSD)
@ 50 to 100 Hz ≥ 3 A
+/-(2.5% + 5 LSD)
@ 100 to 400 Hz ≥ 3 A |
| DC Current(2) |
60.00 / 300.0 A |
+/-(1.5% + 5 LSD)
@ 300 A range |
| Low Pass Filter |
300.0 A |
+/-(3.5% + 5 LSD)
@ 50 to 60 Hz ≥ 3 A |
| True-RMS |
• |
|
| Inrush Current |
• |
|
| Non-Contact Voltage |
• |
|
| Data Hold |
• |
|
(1)Note: Crest Factor (C.F.) may be up to 3.0 as 4000 counts.
For non-sinusoidal waveforms:
Add 3.0% for C.F. 1.0 to 2.0
Add 5.0% for C.F. 2.0 to 2.5
Add 7.0% for C.F. 2.5 to 3.0
Position error of clamp: +/- 1.5 % of LCD reading
(2) Add 10 LSD in auto AC/DC sense mode |