The Hioki IR4053 is a digital insulation resistance tester for photovoltaic generation systems. Measure insulation resistance accurate and safely without being affected by generated solar power and identify the value in just 4 seconds. Safety CAT III 600 V.
HIOKI INSULATION TESTER IR4053 Price in Bangladesh offers reliable and accurate insulation resistance measurement for electrical maintenance and safety. This tester features advanced functions, user-friendly operation, and durable design, making it ideal for professionals and technicians. Get the best value for your investment with competitive pricing and genuine quality. Explore HIOKI INSULATION TESTER IR4053 Price in Bangladesh today for efficient and safe electrical testing solutions.
Key Features
- Safely and accurately measure PV insulation resistance even while generating solar power
- Built-in PV dedicated function, display measurements in 4 seconds
- Five ranges (50/125/250/500/1000V) built in for normal insulation resistance measurement
- Built-in 1000 VDC voltage measurement for open voltage tests of PV systems that support 1000 V
- Built-in comparator function
- Drop proof design withstands drop onto concrete from a height of 1 meter
Basic specifications: PVΩ measurement
Accuracy guaranteed: 1 year
| Rated output voltage |
500 V DC |
1000 V DC |
| Effective maximum indicated value |
2000 MΩ |
4000 MΩ |
| Measuring range/ Accuracy |
0.200 to 500 MΩ / ±4% rdg.
501 to 2000 MΩ / ±8% rdg. |
0.200 to 1000 MΩ / ±4% rdg.
1010 to 4000 MΩ / ±8% rdg. |
| Other measuring range / Accuracy |
0 to 0.199 MΩ / ±2% rdg. ±6 dgt. |
Basic specifications: Insulation resistance measurement
Accuracy guaranteed: 1 year
| Rated output voltage |
50 V DC |
125 V DC |
250 V DC |
500 V DC |
1000 V DC |
| Effective maximum indicated value |
100 MΩ |
250 MΩ |
500 MΩ |
2000 MΩ |
4000 MΩ |
Accuracy
1st effective measuring range MΩ |
±4% rdg.
0.200 to 10.00 |
±4% rdg.
0.200 to 25.0 |
±4% rdg.
0.200 to 50.0 |
±4% rdg.
0.200 to 500 |
±4% rdg.
0.200 to 1000 |
| Lower limit resistance |
0.05 MΩ |
0.125 MΩ |
0.25 MΩ |
0.5 MΩ |
1 MΩ |
| Overload protection |
600 V AC (10 s) |
600 V AC (10 s) |
600 V AC (10 s) |
600 V AC (10 s) |
1200 V DC (10 s) |
| DC voltage range |
4.2 V (0.001 V resolution) to 1000 V (1 V resolution), 4 ranges,
Accuracy: ±1.3% rdg. ±4 dgt., (Ranges in excess of 1000 V are not guaranteed for accuracy.) |
| AC voltage range |
420 V (0.1 V resolution)/600 V (1 V resolution), 2 ranges, 50/60 Hz,
Accuracy: ±2.3% rdg. ±8 dgt., (Ranges in excess of 600 V are not guaranteed for accuracy.) |
| Display |
Semi-transmissive FSTN LCD with back lighting, Backlight |
| Response time |
Insulation resistance range: 1 second, PVΩ function: 4 seconds (based on in-house tests) |
| Other functions |
Live circuit indicator, automatic electric discharge, automatic DC/AC detection, comparator, drop proof, auto power save |
| Power supply |
AA alkaline batteries (LR6) ×4, Continuous operating time: Approx. 20 hours (based on in-house tests) |
| Dimensions and mass |
159 mm (6.26 in) W × 177 mm H (6.97 in) H × 53 mm (2.09 in) D, Approx. 600 g (21.2 oz) (including batteries, excluding test lead) |
| Included accessories |
TEST LEAD L9787 ×1, Neck strap ×1, Instruction manual ×1, AA alkaline batteries (LR6) ×4 |
| Included accessories |
TEST LEAD L9787 ×1, Neck strap ×1, Instruction manual ×1, AA alkaline batteries (LR6) ×4 |
| Included accessories |
TEST LEAD L9787 ×1, Neck strap ×1, Instruction manual ×1, AA alkaline batteries (LR6) ×4 |