Fluke QA-ES III Electrosurgery Analyzer
The QA-ES III Electrosurgical Analyzer simplifies testing to ensure the performance and safety of electrosurgical units. With generator output current accuracy as low as ± 2.5 %, the QA-ES III is capable of testing all modern high-power electrosurgical units. Collect all measurements, including vessel sealing, contact quality monitor (CQM), high frequency (HF) leakage, and output power distribution in single or continuous mode. The QA-ES III has all the hardware and software needed for complete testing, so you don’t need to carry additional accessories or cables. With all-in-one features, the QA-ES III is one of the most user-friendly electrosurgical analyzers on the market today. Additionally, Ansur test automation software allows users to create and automatically run tests, capture data, and produce easy-to-read reports.
• Test all critical ESU functions with precise power, current, frequency, crest factor, and load resistance ranges
• Collect measurements in single and continuous mode
• Automatic power distribution measurement, including power, current, peak-to-peak voltage, and crest factor
• All-in-one tool: all hardware and software necessary to complete preventive maintenance and troubleshooting are built into the unit, eliminating the need to purchase or transport additional cables, leads, switch boxes, and RECM box
• User-friendly interface: large buttons and LCD screen guide the user through test sequences
• Memory storage of up to 5,000 test records, eliminating the need to download data after the completion of each preventive maintenance or troubleshooting session
• Complies with all global standards, including ANSI/AAMI and IEC*
| Product Type |
Electrosurgery Analyzer |
| Power Measurement |
Up to 500 Watts RMS |
| Voltage Range |
± 0.5 V to ± 700 V |
| Current Range |
± 2 mA to ± 650 mA |
| Load Resistance |
0 to 6400 ohms (user-selectable in 5 ohm increments) |
| Crest Factor Measurement |
1.4 to > 10 |
| High-Frequency Leakage |
± 0.5 mA to ± 650 mA |
| Output Waveform Display |
True RMS (no need for oscilloscope) |
| Modes Supported |
Monopolar Cut, Coag, Bipolar, Blend, and others |
| Duty Cycle Measurement |
Yes |
| Touch Screen Display |
Color LCD, touch-enabled |
| Test Automation |
Yes (Auto-sequence test setup) |
| Internal Memory |
Stores up to 5000 test records |
| Interface |
USB, LAN, RS-232 |
| Power Requirements |
100–240 V AC, 50/60 Hz |
| Dimensions (H x W x D) |
Approx. 114 mm x 273 mm x 330 mm |
| Safety Standards |
IEC 60601-1, IEC 60601-2-2 |
| Calibration |
Annual recommended |
| Accessories Included |
Test Leads, Power Cable, User Manual, Carrying Case |