Testo 480 Digital temperature is the best product in this year and the Testo 480 Digital temperature is Air flow measurements in ducts, temperature measurements in laboratories, humidity measurements in production, pressure difference measurements in clean rooms. The testo 480 digital temperature, humidity, and consent to breathe flow meter comes taking into account a broad range of optional sensors that vent you to act, analyze and log these and a variety of connection parameters when lonesome one device.
Key Features: Testo 480 Digital temperature
-
High-quality optional sensors for measuring air flow, temperature, humidity, pressure, degree of turbulence, heat radiation, CO2, illumination intensity, PMV/PPD and WBGT
-
High-precision, integrated pressure sensor included
-
Pro-software for easy and efficient analysis and logging included
-
Intelligent calibration concept
Specifications: Testo 480 Digital temperature
| Temperature - Pt100 |
|
Measuring range
|
-100 to +400 °C
|
|
Resolution
|
0.01 °C
|
| Temperature - TC Type K (NiCr-Ni) |
|
Measuring range
|
-200 to +1370 °C
|
|
Accuracy
|
±(0.3 °C + 0.1 % of mv)
|
|
Resolution
|
0.1 °C
|
| Humidity - Capacitive |
|
Measuring range
|
0 to 100 %RH
|
|
Resolution
|
0.1 %RH
|
| Velocity - Vane |
|
Measuring range
|
0.6 to +50 m/s (vane anemometer Ø 16 mm)
0.1 to +15 m/s (vane anemometer Ø 100 mm)
|
|
Resolution
|
0.1 m/s (vane anemometer Ø 16 mm)
0.01 m/s (vane anemometer Ø 100 mm)
|
| Velocity - Hot wire |
|
Measuring range
|
0 to +20 m/s
|
|
Resolution
|
0.01 m/s
|
| Ambient CO₂ |
|
Measuring range
|
0 to 10000 ppm CO₂
|
|
Resolution
|
1 ppm CO₂
|
| Comfort level measurement |
|
Measuring range
|
0 to +5 m/s
|
|
Resolution
|
0.01 m/s
|
| Differential pressure (internal sensor) - Piezoresistive |
|
Measuring range
|
-100 to +100 hPa
|
|
Accuracy
|
±(0.3 Pa + 1 % of mv) (0 to +25 hPa)
±(0.1 hPa + 1.5 % of mv) (+25.001 to +100 hPa)
|
|
Resolution
|
0.001 hPa
|
| Light |
|
Measuring range
|
0 to 100000 Lux
|
|
Resolution
|
1 Lux
|
| Absolute Pressure (internal sensor and external probe) |
|
Measuring range
|
700 to 1100 hPa
|
|
Accuracy
|
±3 hPa
|
|
Resolution
|
0.1 hPa
|
| General technical data |
|
Operating temperature
|
0 to +40 °C
|
|
Protection class
|
IP30
|
|
Connectable probes
|
2 x Temperature TC Type K, 1 x differential pressure (internal), 3 x digital
|
|
EU-/EG-guidelines
|
2004/108/EG
|
|
Battery life
|
approx. 17 hours (hand instrument without probes, with 50 % display brightness)
|
|
Display function
|
Colour graphic display
|
|
Power supply
|
Rechargeable battery, plug-in mains unit for long-term measurements and charging battery
|
|
Data transfer
|
USB cable or SD card
|
|
Memory
|
60,000,000 measuring values
|
|
Storage temperature
|
-20 to +60 °C
|
|
Weight
|
435 g
|