Testo 330 2 LL Professional long-life set is workable that is rugged reliable and trusted. Ready to make a get your hands on of started roughly the subject of the most important tasks on the go in flue gas analysis upon oil, gas and sealed fuel systems: the testo 330-2 LL professional long-energy set offers the possibility of flue gas measurement, draught, pressure and ambient CO/CO2 measurements, differential temperature measurement and gas leak detection.
Key Features: Testo 330 2 LL Professional long life set
-
330-2 LL flue gas analyzer with fresh air valve to protect the CO measuring cell and to extend the CO measuring range to 30,000 ppm
-
4-year warranty on the probes which users can change themselves, including sensor monitoring with a service life of up to 6 years
-
Single-hose connection: just one hand movement is needed to securely connect all the channels for flue gas measurement (gas paths, draught, temperature probe integrated into the flue gas probe)
-
TÜV-tested according to 1st German Federal Immission Control Ordinance (BImSchV) EN 50379, Parts 1-3
Specifications: Testo 330 2 LL Professional long life set
| Differential Pressure - Piezoresistive |
|
Measuring range
|
±10000 Pa
|
|
Accuracy
|
±0.3 Pa (0 to 9.99 Pa) plus ±1 Digit
±3 % of mv (10 to 10000 Pa) plus ±1 Digit
|
| Flue gas O₂ |
|
Measuring range
|
0 to 21 Vol.%
|
|
Accuracy
|
±0.2 Vol.%
|
|
Resolution
|
0.1 Vol.%
|
|
Reaction time t₉₀
|
< 20 s
|
| Flue gas CO (with H₂-compensation) |
|
Measuring range
|
0 to 8000 ppm
|
|
Accuracy
|
±10 ppm or ±10 % of mv (0 to 200 ppm)
±20 ppm or ±5 % of mv (201 to 2000 ppm)
±10 % of mv (2001 to 8000 ppm)
|
|
Resolution
|
1 ppm
|
|
Reaction time t₉₀
|
< 60 s
|
| Flue gas COlow |
|
Measuring range
|
0 to 500 ppm
|
|
Accuracy
|
±2 ppm (0 to 39.9 ppm)
±5 % of mv (40 to 500 ppm)
|
|
Resolution
|
0.1 ppm
|
|
Reaction time t₉₀
|
< 40 s
|
| CO determination (with H₂-compensation), automatic dilution |
|
Measuring range
|
0 to 30000 ppm
|
|
Accuracy
|
±100 ppm (0 to 1000 ppm)
±10 % of mv (1001 to 30000 ppm)
|
|
Resolution
|
1 ppm
|
| Flue gas NO |
|
Measuring range
|
0 to 3000 ppm
|
|
Accuracy
|
±5 ppm (0 to 100 ppm)
±5 % of mv (101 to 2000 ppm)
±10 % of mv (2001 to 3000 ppm)
|
|
Resolution
|
1 ppm
|
|
Reaction time t₉₀
|
< 30 s
|
| Flue gas Nolow |
|
Measuring range
|
0 to 300 ppm
|
|
Accuracy
|
±2 ppm (0 to 39.9 ppm)
±5 % of mv (40 to 300 ppm)
|
|
Resolution
|
0.1 ppm
|
|
Reaction time t₉₀
|
< 30 s
|
| Flue gas Draught |
|
Measuring range
|
-9.99 to +40 hPa
|
|
Accuracy
|
±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)
±0.03 hPa (+0.61 to +3.00 hPa)
±1.5 % of mv (+3.01 to +40.00 hPa)
|
|
Resolution
|
0.01 hPa
|
| Temperature |
|
Measuring range
|
-40 to +1200 °C
|
|
Accuracy
|
±0.5 °C (0 to +100.0 °C)
±0.5 % of mv (Remaining Range)
|
|
Resolution
|
0.1 °C (-40 to +999.9 °C)
1 °C (> +1000 °C)
|
| Flue gas degree of effectivity, Eta (calculated) |
|
Measuring range
|
0 to 120 %
|
|
Resolution
|
0.1 %
|
| Flue gas loss (calculated) |
|
Measuring range
|
0 to 99.9 %
|
|
Resolution
|
0.1 %
|
| Flue gas CO₂ calculation (calculated from O₂) |
|
Measuring range
|
0 to CO₂ max (Display range)
|
|
Accuracy
|
±0.2 Vol.%
|
|
Resolution
|
0.1 Vol.%
|
|
Reaction time t₉₀
|
< 40 s
|
| Velocity / Volume flow |
|
Measuring range
|
0.15 to 3 m/s
|
|
Resolution
|
0.1 m/s
|
| Pressure measurement |
|
Measuring range
|
0 to +300 hPa
|
|
Accuracy
|
±0.5 hPa (0.0 to 50.0 hPa)
±1 % of mv (50.1 to 100.0 hPa)
±1.5 % of mv (Remaining Range)
|
|
Resolution
|
0.1 hPa
|
| Flue gas CO (without H₂-compensation) |
Real people, here to help you.
Get Connected
Join the community and find out what we're up to, experience live product releases, webinars and
more!
|