Kyoristu 6016 provides stockpile RCD investigation for RCD type A (pulsating lecture to currents), RCD type AC (every substitute currents), general and selective RCDs (delayed). Measurements can be at 0.5, 1 and 5 become outdated the rated nominal RCD current. Featuring both autotest and ramp functions, the 6016 has selectable adjoin voltage (25V and 50V) to dispute the application.

Furthermore, 6016 can be utilized to pretend both earth resistance and three-phase rotation. Earth resistance can be measured going on to 2000. This can be undertaken using the volt-ampere method without an uncovered realization source and in imitation of the supplied press on spikes. The 6016 can be applied to perform the phase rotation of three-phase lines as soon as a determined indication of the sequence upon the LCD display.

Key Features: Kyoritsu KEW 6016 Multi Function Testers

  • Continuity measurements up to 2000Ω
  • Three phase rotation testing 
  • RCD testing with ramp and autotest functions
  • Lockdown test button for "hands-free testing"
  • Calculation of Prospective Short Current (PSC) and Prospective Fault Current (PFC).
  • Loop impedance testing including phase to phase loops.
  • Measures AC voltages up to 500V (includes frequency of voltage).
  • Earth resistance measurements up to 2000Ω
  • Supplied with carry case, test leads, auxiliary spikes and software.

Specifications: Kyoritsu KEW 6016 Multi Function Testers

Continuity
Range 20/200/2000Ω (Auto-ranging)
 Open circuit
voltage (DC)
5V±20% (*1)
Short circuit
current
Greater than 200mA
Accuracy  ±0.1Ω (0 - 0.19Ω)
±2%rdg+8dgt (0.2 - 2000Ω) 
Insulation Resistance
Range 20/200MΩ
(Auto-ranging)
20/200/2000MΩ (Auto-ranging)
Open circuit
voltage (DC)
250V+25% -0% 500V+25% -0% 1000V+20% -0%
Rated current 1mA or greater
@ 250kΩ 
1mA or greater
@ 500kΩ
1mA or greater
@ 1MΩ
Accuracy ±2%rdg+6dgt
(0 - 19.99MΩ)
±5%rdg+6dgt
(20 - 200MΩ)
±2%rdg+6dgt (0 - 199.9MΩ)
±5%rdg+6dgt (200 - 2000MΩ)
Loop Impedance
Function L-PE L-PE (ATT) L-N / L-L
Rated Voltage 100 - 260V 50/60Hz L-N: 100 - 300V
L-L: 300 - 500V
50/60Hz
Nominal Test
Current at 0Ω
External Loop:
Magnitude/
Duration (*2)
20Ω: 6A/20ms
200Ω: 2A/20ms
2000Ω: 15mA/500ms
L-N: 6A/60ms
N-PE: 10mA/approx. 5s
20Ω: 6A/20ms
Range 20/200/2000Ω
(Auto-ranging)
20/200/2000Ω
(Auto-ranging)
(L-N < 20Ω)
20Ω
Accuracy ±3%rdg+4dgt(*3)
±3%rdg+8dgt(*4)
±3%rdg+6dgt (*3)
±3%rdg+8dgt(*4)
±3%rdg+4dgt (*3)
±3%rdg+8dgt(*4)  
PSC (L-N / L-L) / PFC (L-PE)
Function PSC PFC PFC (ATT)
Rated Voltage 100 - 500V 50/60Hz 100 - 260V 50/60Hz  
Nominal Test
Current at 0Ω
External Loop:
Magnitude/
Duration (*5)
6A/20ms 6A/20ms
2A/20ms
15mA/500ms
L-N: 6A/60ms
N-PE: 10mA/approx. 5s 
 Range 2000A/20kA Auto-Ranging
Accuracy PSC / PFC accuracy is derived from measured loop impedance
specification and measured voltage specification
RCD
Function X1/2 X1 X5 Ramp Auto
Trip current
setting
10/30/100/300/
500/1000mA
10/30/
100mA   
10/30/
100/300/
500mA
Depending on the
accuracy at each
function.
Measurement sequence:
X1/2 0°→X1/2 180°
→X1 0°→X1 180°
→X5 0°→X5 180°
Measurements with
x5 are not carried out
for RCDs with
nominal current of
100mA or more.
Trip current
Duration
2000ms G: 550ms
S: 1000ms
410ms Goes up by
10% from
20% to
110%
G:300ms/
S:500ms
X10 times
Rated Voltage 230V+10%-15% 50/60Hz
Accuracy AC Type:
-8% - -2%
A Type:
-10% - 0%
AC Type: +2% - +8%
A Type: 0% - +10%
AC Type: ±4%
A Type: ±10%
Trip time: ±1%rdg+3dgt
RCD (Uc)
Function UC
Rated Voltage 230V+10% - 15% 50/60Hz
Range 100.0V
Test current ≤ 1/2IΔn (max150mA)
Accuracy +5% - +15%rdg, ±8dgt
Earth
Range 20/200/2000Ω Auto-Ranging
Accuracy 20Ω: ±3%rdg+0.1Ω
200/2000Ω: ±3%rdg+3dgt (Auxiliary earth resistance 100±5%)
Phase Rotation
Rated Voltage 50-500V 50/60Hz
Remarks Correct phase sequence: are displayed "1.2.3" and  cycle mark
Reversed phase sequence: are displayed "3.2.1" and  cycle mark
Volts
Function Volts Frequency
Rated Voltage 25 - 500V, 45 - 65Hz
Measuring range  25 - 500V 45 - 65Hz
Accuracy ±2%rdg+4dgt ±0.5%rdg+2dgt

 

Applicable standards IEC 61010-1 CAT III 300V (500V L to L) Pollution degree 2, IEC 61010-031,
IEC 61557-1, 2, 3, 4, 5, 6, 7, 10, IEC 60529 (IP40), IEC 61326 (EMC)
Power source LR6 X 8
Dimensions 136(L) X 235(W) X 114(D)mm
Weight 1350g (including batteries.)
Included Accessories 7188A (Distribution board fuse test lead set)
7196A (Test leads with remote control switch)
7218A (Power cord [EU]) (*6)
7228A (Earth resistance test leads)
8032 (Auxiliary earth spikes)
8212-USB (USB adaptor with KEW Report (Software))
9142 (Carrying case)
9121 (Shoulder strap)
Cord case, Buckle, Battery, Instruction manual
Optional Accessories 8212-RS232C (RS232C adaptor with KEW Report (Software))
  • N/A
  • N/A
seller

Sellers

Connect your real buyer on Tools Bangaldesh where visit the maximum customer for Tools In Bangladesh.

e-marketplace

e-Marketplace

Tools Bangladesh is a Trustworthy e-Marketplace in Bangladesh. Connect buyer and seller on the trade fair.

growth

Buyers

Get the reliable and authentic Tools at the best price in Bangladesh with on time delivery entire Bangladesh.