Model: Fluke T6-1000 Electrical Tester
Fluke T6 1000 Electrical Tester is very productive. Fluke is not only for the best results but also We know operating in electrical boxes packed with wires may be difficult once you’re attempting to seek out a secure gold contact purpose.
Now, with Fluke T6-600 or T6-1000 with integrated FieldSense technology, you'll be able to quickly and simply take measurements by slippery the open deliver a conductor to visualize the voltage level without the need for test leads.
You never careless to get it because this model is stock limited for Bangladesh. So, quick order now at Tools Bangladesh and we can keep the ability to free delivery anywhere in Bangladesh.
Fluke T6-1000 Electrical Tester
Key features
- Be safer: Measure voltage to 1000 V Ac through the open fork, without test leads.
- Be faster: No need to open covers or remove wire nuts.
- Go beyond simple detection. Actually,y measure ac voltage and current values without test leads.
- Be everywhere: 17.8 mm open fork is widest in the industry; measure up to 200 A on 4/0 wires (120 mm2).
- Be more efficient: Simultaneously measure voltage and current.
Specifications: Fluke T6-1000 Electrical Tester
| Measurement Specifications |
| Function |
Requires test leads |
Range |
Resolution |
Accuracy[1] |
FieldSense
ac voltage true-rms |
No |
1000 V |
1 V |
± (3 % + 3 counts) 45 Hz - 66 Hz[2][3] |
FieldSense
ac current true-rms |
No |
200.0 A |
0.1 A |
± (3% + 3 counts) 45 Hz - 66 Hz |
FieldSense
frequency (Hz) |
No |
45 Hz – 66 Hz |
1 Hz |
± (1% + 2 counts)[3] |
| Volts ac true-rms |
Yes |
1000 V |
1 V |
± (1.5% + 2 counts) 45 Hz - 66 Hz |
| Volts dc |
Yes |
1000 V |
1 V |
± (1% + 2 counts) |
| Resistance |
Yes |
2000 Ω |
1 Ω |
± (1% + 2 counts) |
| Yes |
20.00 kΩ |
0.01 kΩ |
| Yes |
100.0 kΩ |
0.1 kΩ |
| Safety |
|
1000 V CAT III
600 V CAT IV |
|
|
|
Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.
Accuracy[2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.
Accuracy[3]: FieldSense is specified from 16 V to 100 % of range.
|
| General Specifications |
| Calibration |
1-year calibration cycle |
| Dimensions |
61.1 x 259.3 x 43.8 mm |
| Jaw opening |
17.8 mm |
| Weight |
0.35 kg (0.78 lb) |
| Temperature |
Operating |
-10 °C to +50 °C (14 °F to 122 °F) |
| Storage |
-30 °C to +60 °C (-22 °F to +140 °F) |
| Altitude |
Operating |
2,000 m (6,562 feet) |
| Storage |
10,000 m (32,808 feet) |
| Relative Humidity |
0% to 90%, 5 °C to 30 °C (41 °F to 86 °F) |
| 0% to 75%, 30°C to 40 °C (86 °F to 104 °F) |
| 0% to 45%, 40°C to 50 °C (104 °F to 122 °F) |
| Battery Type and Life |
2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense |
| Temperature coefficient |
0.1 x (specified accuracy) / °C for <18°C or >28 °C |
| 0.1 x (specified accuracy) / °C for <18°C or >28 °C |
| Safety |
IEC/EN 61010-1: Pollution Degree 2 |
| Electromagnetic Environment |
IEC/EN 61326-1: Portable |
Fluke T6-1000 Electrical Tester
Includes:
- Attached test leads with removable 4 mm probe caps
- User documentation
Accessories: Fluke T6-1000 Electrical Tester
- Carrying Cases
- Fluke C33 Soft Meter Carrying Case C33
- Fluke C33 Soft Meter Carrying Case.
- Included with the 330 Series.