Hioki DC resistance meters measure a broad range of resistance values at a high level of precision. The RM3543 is designed to be integrated into current sensing resistor taping machines, deliver high-accuracy measurement of super-low-resistance levels, and are advanced enough to measure 0.1 mΩ shunts with room to spare.
Get precision testing equipment from global brands. The HIOKI RESISTANCE HiTESTER RM3543 Price in Bangladesh offers great value for high-performance resistance measurement, ensuring reliability in every industrial application. Ideal for quality control and production lines.
Key Features
- Advanced enough to measure 0.1 mΩ shunts with room to spare at ±0.16% accuracy & 0.01μΩ resolution performance
- Superb repeatable measurement accuracy
- Advanced contact-check, comparator, and data export functions
- Intuitive user interface and strong noise immunity are ideal for automated systems
Basic specifications
Accuracy guaranteed: 1 year
| Measurement method |
Four-terminal, constant-current DC |
| Resistance range |
10 mΩ (Max. 12.00000 mΩ, 0.01 μΩ resolution) to 1000 Ω range (Max. 1200.000 Ω, 1 mΩ resolution), 7 steps |
| Display |
Monochrome graphic LCD 240 × 64 dot, white LED backlight |
| Measurement accuracy |
[at 10 mΩ range, with SLOW mode, average 16 times settings]
±0.060 % rdg. ±0.001 % f.s. |
| Testing current |
[at 10 mΩ range] 1 A DC to [at 1000 Ω range] 1 mA DC |
| Open-terminal voltage |
20 V DC max. Note: Voltage when not measuring is 20 mV or less, with current mode set at PULSE and Contact Improver Setting set at OFF/PULSE (measured with a voltmeter having 10 MΩ) |
| Sampling rate |
FAST, MEDIUM, SLOW, 3 settings |
| Integration time |
[at 10 mΩ range, default value] FAST 2.0 ms, MED 5.0 ms, SLOW 1 PLC,
Setting range: 0.1 ms to 100.0 ms, or 1 to 5 PLC at 50 Hz, 1 to 6 PLC at 60 Hz Note: PLC = one power line cycle (mains wave-form period) |
| Other functions |
Comparator (compare setting value with measurement value), Delay, OVC (offset voltage compensation), Average, Measurement fault detection, Probe short-circuit detection, Improve contact, Current mode setting (A pulse application function that applies current only during measurement), Auto-memory, Statistical calculations, Settings monitor (when using two instruments, a difference in settings causes warning notification), Retry, Trigger function. etc,. |
| Interfaces |
External I/O, RS-232C, Printer, GP-IB (Model RM3543-01) |
| External I/O |
Trigger, Hold input, Comparator output, Settings monitor terminal, Service power output +5V, +12V, etc. |
| Power supply |
100 to 240 V AC, 50/60 Hz, 40 VA max. |
| Dimensions and mass |
260 mm (10.24 in) W × 88 mm (3.46 in) H × 300 mm (11.81 in) D, 3.0 kg (105.8 oz) |
| Included accessories |
Power cord ×1, EXT. I/O male connector ×1, Instruction manual ×1, Operation guide ×1 |
| Included accessories |
Power cord ×1, EXT. I/O male connector ×1, Instruction manual ×1, Operation guide ×1 |
| Included accessories |
Power cord ×1, EXT. I/O male connector ×1, Instruction manual ×1, Operation guide ×1 |