Hioki's pass-through type AC/DC current sensors can be connected directly to Hioki Power Analyzers and Memory HiCorders. Also, it can be connected to Power Meters, Oscilloscopes, DMMs, etc. by using an optional sensor unit.
The CT6904A-2 has a frequency bandwidth of DC to 4 MHz (Model CT6904A-3 is DC to 2 MHz) and a rated current of 800 A. It is used in research and development fields such as loss measurement of high-frequency reactors, wireless charging systems, and EV inverter motors.

Key Features

  • Combined accuracy with HIOKI power analyzer PW8001 and PW6001 is specified. For details of combined accuracy, refer to the instruction manual.
  • 800 A (rms) rated for measurement of large currents
  • CT6904A-2: DC to 4 MHz (±3 dB), CT6904A-3: DC to 2 MHz (±3 dB) wide measurement frequency range
  • 120 dB (100 kHz) high Common-Mode Rejection Ratio (CMRR)

Basic specifications

Accuracy guaranteed: 1 year

Rated current 800 A AC/DC
Max. allowable input Within the derating range, However, up to ±1200 A peak is allowable if within 20 ms. (design value)
Frequency bandwidth Amplitude: DC to 4 MHz (CT6904A-2), DC to 2 MHz (CT6904A-3)
Phase: DC to 1 MHz
Linearity ±12.5 ppm Typical (23°C (73°F))
Offset voltage ±10 ppm Typical (23°C (73°F), no input)
Basic accuracy DC (Amplitude: ±0.030 % rdg. ±0.009 % f.s., No phase specification)
45 Hz ≤ f ≤ 65 Hz (Amplitude: ±0.025 % rdg. ±0.009 % f.s., Phase: ±0.08°)
Output voltage rate 2 mV / A rated (This device outputs AC+DC voltage via the Sensor Unit)
Max. rated voltage to earth 1000 V CAT III
Core diameter φ 32 mm (1.26 in)
Operating temperature, humidity -10°C to 50°C (14°F to 122°F)
80% RH or less (with no condensation)
Power supply Power suppled via the Power Analyzer PW8001, PW6001, PW3390, or Sensor Unit CT9555, CT9556, CT9557
Max. rated power 7 VA Max. (800 A/55 Hz measurement, with a power supply of ±12 V)
Dimensions and mass 139 mm (5.47 in)W × 120 mm (4.72 in)H × 52 mm (2.05 in)D, CT6904A-2: 1.15 kg (40.6 oz), cable length 3 m (9.84 ft), CT6904A-3: 1.45 kg (51.1 oz), cable length 10 m (32.81 ft)
Included accessories Instruction Manual ×1, Carrying case ×1, Color labels (for channel identification) ×1, Operating Precautions ×1
Included accessories Instruction Manual ×1, Carrying case ×1, Color labels (for channel identification) ×1, Operating Precautions ×1
Included accessories Instruction Manual ×1, Carrying case ×1, Color labels (for channel identification) ×1, Operating Precautions ×1

Hioki's pass-through type AC/DC current sensors can be connected directly to Hioki Power Analyzers and Memory HiCorders. Also, it can be connected to Power Meters, Oscilloscopes, DMMs, etc. by using an optional sensor unit.
The CT6904A-2 has a frequency bandwidth of DC to 4 MHz (Model CT6904A-3 is DC to 2 MHz) and a rated current of 800 A. It is used in research and development fields such as loss measurement of high-frequency reactors, wireless charging systems, and EV inverter motors.

Key Features

  • Combined accuracy with HIOKI power analyzer PW8001 and PW6001 is specified. For details of combined accuracy, refer to the instruction manual.
  • 800 A (rms) rated for measurement of large currents
  • CT6904A-2: DC to 4 MHz (±3 dB), CT6904A-3: DC to 2 MHz (±3 dB) wide measurement frequency range
  • 120 dB (100 kHz) high Common-Mode Rejection Ratio (CMRR)

Basic specifications

Accuracy guaranteed: 1 year

Rated current 800 A AC/DC
Max. allowable input Within the derating range, However, up to ±1200 A peak is allowable if within 20 ms. (design value)
Frequency bandwidth Amplitude: DC to 4 MHz (CT6904A-2), DC to 2 MHz (CT6904A-3)
Phase: DC to 1 MHz
Linearity ±12.5 ppm Typical (23°C (73°F))
Offset voltage ±10 ppm Typical (23°C (73°F), no input)
Basic accuracy DC (Amplitude: ±0.030 % rdg. ±0.009 % f.s., No phase specification)
45 Hz ≤ f ≤ 65 Hz (Amplitude: ±0.025 % rdg. ±0.009 % f.s., Phase: ±0.08°)
Output voltage rate 2 mV / A rated (This device outputs AC+DC voltage via the Sensor Unit)
Max. rated voltage to earth 1000 V CAT III
Core diameter φ 32 mm (1.26 in)
Operating temperature, humidity -10°C to 50°C (14°F to 122°F)
80% RH or less (with no condensation)
Power supply Power suppled via the Power Analyzer PW8001, PW6001, PW3390, or Sensor Unit CT9555, CT9556, CT9557
Max. rated power 7 VA Max. (800 A/55 Hz measurement, with a power supply of ±12 V)
Dimensions and mass 139 mm (5.47 in)W × 120 mm (4.72 in)H × 52 mm (2.05 in)D, CT6904A-2: 1.15 kg (40.6 oz), cable length 3 m (9.84 ft), CT6904A-3: 1.45 kg (51.1 oz), cable length 10 m (32.81 ft)
Included accessories Instruction Manual ×1, Carrying case ×1, Color labels (for channel identification) ×1, Operating Precautions ×1

Included accessories Instruction Manual ×1, Carrying case ×1, Color labels (for channel identification) ×1, Operating Precautions ×1

Included accessories Instruction Manual ×1, Carrying case ×1, Color labels (for channel identification) ×1, Operating Precautions ×1
seller

Sellers

Connect your real buyer on Tools Bangaldesh where visit the maximum customer for Tools In Bangladesh.

e-marketplace

e-Marketplace

Tools Bangladesh is a Trustworthy e-Marketplace in Bangladesh. Connect buyer and seller on the trade fair.

growth

Buyers

Get the reliable and authentic Tools at the best price in Bangladesh with on time delivery entire Bangladesh.