Product overview: Fluke Calibration P3000 Pneumatic Deadweight Testers

This versatile instrument provides calibrations from 1-30 inHg vacuum (0.03-1 bar) and 3-500 psi (0.2-35 bar) in one extremely accurate yet easy to use primary standard. A selector valve converts the unit from pressure to vacuum mode without the need to exchange pistons. Units are manufactured to the highest standards with certified accuracies traceable to International Standards Laboratories such as the National Institute of Standards and Technology (NIST). These piston/cylinder type pneumatic standards provide excellent stability, repeatability and accuracy. An optional built-in hand pump can be added for both pressure and vacuum generation.

Key Features

  • 0.015% of reading accuracy standard (0.008% optional)
  • 1-30 inHg vacuum (0.03-1 bar vacuum)
  • 3-500 psi (0.2-35 bar) pressure
  • inH2O and mbar ranges available
  • Series 3 non-magnetic stainless steel weights
  • Units can be trimmed to local gravity FOC

Specifications: Fluke Calibration P3000 Pneumatic Deadweight Testers

Accuracy
Accuracy1 ±0.015% of reading (±0.008% optional)
1. Accuracy based on % of reading from 10% to 100% of the piston range when used in accordance with the corrections found on the calibration certificate. Below 10% ± (accuracy class) x 10% of the piston range.
Mass and PCU Materials of Construction
Standard weight material Series 3 non-magnetic austenitic stainless steel
Weight density 7.8 g/cm³
Optional fractional weights Solution heat treated aluminum
Weight density 2.7 g/cm³
Models P3011, P3012, P3013, P3022, P3023, P3025 (V) Piston material Ceramic
Cylinder material Martensitic steel
Coefficient of expansion 11 ppm/°C
Models P3014, P3015, P3025 (P) P3031, P3032 (P & V) Piston material Tungsten carbide
Cylinder material Martensitic steel
Coefficient of expansion 16.5 ppm/°C
Model P3016 Piston material Tungsten carbide
Cylinder Material Tungsten carbide
Coefficient of Expansion 11 ppm/°C
General
Test port adaptors 1/8, 1/4, 3/8 and ½ NPT or BSP
Instrument weight 24 lbs
Instrument size (W x D x H) 17.5 x 12 x 8.5
Mass set weight (typical) 65 lbs
Minimum Standard Weight Increments
P3012, P3022 Pressure 1 inH2O, (5 mbar)
P3013, P3023 Pressure 2 inH2O, (10 mbar)
P3014, P3015, P3025 Pressure 1 psi, (0.1 bar)
P3016, P3031, P3032 1 psi, (0.1 bar)
P3011, P3022, P3023, P3025 Vacuum 0.2 inHg (10 mbar)
Optional Fractional Weights
P3014, P3015, P3025 Pressure 0.1 psi (0.01 bar)
Built-in Hand Pumps
Pressure mode Max pressure 300 psi (20 bar)
Vacuum mode To 90% vacuum
Operating Fluid for Liquid Lubricated Models
55-655 Mineral oil (standard)
Krytox For oxygen-safe applications (optional)
Options
PressCal Software Windows-based software program that allows users to easily apply all necessary corrections to enhance the deadweight tester performance. Calibration details are then stored and/or used to automatically create a calibration certificate. PressCal is provided as standard with all 0.008% instruments.
Krytox As operating fluid for liquid lubricated gas operated models.

Accessories: Fluke Calibration P3000 Pneumatic Deadweight Testers

Adapters and cables (2)

Accessories: Fluke Calibration P3000 Pneumatic Deadweight Testers

Adapters and cables (2)

Product overview: Fluke Calibration P3000 Pneumatic Deadweight Testers

This versatile instrument provides calibrations from 1-30 inHg vacuum (0.03-1 bar) and 3-500 psi (0.2-35 bar) in one extremely accurate yet easy to use primary standard. A selector valve converts the unit from pressure to vacuum mode without the need to exchange pistons. Units are manufactured to the highest standards with certified accuracies traceable to International Standards Laboratories such as the National Institute of Standards and Technology (NIST). These piston/cylinder type pneumatic standards provide excellent stability, repeatability and accuracy. An optional built-in hand pump can be added for both pressure and vacuum generation.

Key Features

  • 0.015% of reading accuracy standard (0.008% optional)
  • 1-30 inHg vacuum (0.03-1 bar vacuum)
  • 3-500 psi (0.2-35 bar) pressure
  • inH2O and mbar ranges available
  • Series 3 non-magnetic stainless steel weights
  • Units can be trimmed to local gravity FOC

Specifications: Fluke Calibration P3000 Pneumatic Deadweight Testers

Accuracy
Accuracy1 ±0.015% of reading (±0.008% optional)
1. Accuracy based on % of reading from 10% to 100% of the piston range when used in accordance with the corrections found on the calibration certificate. Below 10% ± (accuracy class) x 10% of the piston range.
Mass and PCU Materials of Construction
Standard weight material Series 3 non-magnetic austenitic stainless steel
Weight density 7.8 g/cm³
Optional fractional weights Solution heat treated aluminum
Weight density 2.7 g/cm³
Models P3011, P3012, P3013, P3022, P3023, P3025 (V) Piston material Ceramic
Cylinder material Martensitic steel
Coefficient of expansion 11 ppm/°C
Models P3014, P3015, P3025 (P) P3031, P3032 (P & V) Piston material Tungsten carbide
Cylinder material Martensitic steel
Coefficient of expansion 16.5 ppm/°C
Model P3016 Piston material Tungsten carbide
Cylinder Material Tungsten carbide
Coefficient of Expansion 11 ppm/°C
General
Test port adaptors 1/8, 1/4, 3/8 and ½ NPT or BSP
Instrument weight 24 lbs
Instrument size (W x D x H) 17.5 x 12 x 8.5
Mass set weight (typical) 65 lbs
Minimum Standard Weight Increments
P3012, P3022 Pressure 1 inH2O, (5 mbar)
P3013, P3023 Pressure 2 inH2O, (10 mbar)
P3014, P3015, P3025 Pressure 1 psi, (0.1 bar)
P3016, P3031, P3032 1 psi, (0.1 bar)
P3011, P3022, P3023, P3025 Vacuum 0.2 inHg (10 mbar)
Optional Fractional Weights
P3014, P3015, P3025 Pressure 0.1 psi (0.01 bar)
Built-in Hand Pumps
Pressure mode Max pressure 300 psi (20 bar)
Vacuum mode To 90% vacuum
Operating Fluid for Liquid Lubricated Models
55-655 Mineral oil (standard)
Krytox For oxygen-safe applications (optional)
Options
PressCal Software Windows-based software program that allows users to easily apply all necessary corrections to enhance the deadweight tester performance. Calibration details are then stored and/or used to automatically create a calibration certificate. PressCal is provided as standard with all 0.008% instruments.
Krytox As operating fluid for liquid lubricated gas operated models.

Accessories: Fluke Calibration P3000 Pneumatic Deadweight Testers

Adapters and cables (2)

Accessories: Fluke Calibration P3000 Pneumatic Deadweight Testers

Adapters and cables (2)

seller

Sellers

Connect your real buyer on Tools Bangaldesh where visit the maximum customer for Tools In Bangladesh.

e-marketplace

e-Marketplace

Tools Bangladesh is a Trustworthy e-Marketplace in Bangladesh. Connect buyer and seller on the trade fair.

growth

Buyers

Get the reliable and authentic Tools at the best price in Bangladesh with on time delivery entire Bangladesh.