Shop : Tools Bangladesh
Product ID : 3972
Brand : Fluke
Availability : In Stock (1)
Price BDT : Ask for Price
Reviews :
Share :
Request Quote
  • Customer Support

    +8801965656380
  • Cash One Delivery

    Pay after getting the product on hand
  • Warranty

    1 Year warranty by manufacturer
  • Secured Payment Method

    Your cart is always secure to shop
  • Easy Return Policy

    24 hours return without physical defect.

Product overview: Fluke Calibration 9103/9140 Field Dry-Well

Portable, fast, and accurate temperature sources for on-site calibration

Exceptional Performance in a Compact Design

The Fluke 9103 and 9140 Field Dry-Wells outperform the competition in nearly every category—performance, size, weight, ease of use, calibration simplicity, software integration, and price.

Each unit features:

  • Adjustable heating and cooling rates via the front panel
  • Thermal switch actuation testing
  • Multiple-hole inserts for compatibility with a wide range of probe sizes

Fast Calibration with Minimal Downtime

  • Units are easy to calibrate without opening the case, reducing maintenance costs and downtime
  • All units include a NIST-traceable calibration certificate at no additional charge
  • Factory-tested for accuracy and reliability before shipment

Software Integration

Fluke’s Interface-it software supports:

  • Set-point and ramp rate control
  • Real-time temperature logging
  • Electronic strip chart creation
  • Thermal switch test automation with data collection
  • Windows-based interface with intuitive graphical controls

Whether you need basic control or full automation, Fluke has a software solution ready.

Fluke 9103 – Low-Temperature Field Dry-Well

  • Temperature Range: Down to –25 °C (actual, not below ambient)
  • Stability: ±0.02 °C
  • Display Accuracy: ±0.25 °C across full range
  • Speed:
    • Reaches 0 °C in 8 minutes
    • Reaches 100 °C in 6 minutes

Key Advantage:

Many competitors advertise –45 °C below ambient, which only reaches around –20 °C. The 9103 delivers a true –25 °C in standard room conditions—no walk-in freezer required.

Insert Options:

Choose from four removable inserts to suit your calibration needs:

  • Insert A: One well each from 1/16” to 1/2”
  • Insert B: Two wells each of 3/8”, 1/4”, and 3/16” (ideal for comparison calibrations)
  • Insert C: Six 1/4” wells for multiple probe calibrations
  • Insert D: Three pairs of metric-sized wells

Fluke 9140 – Mid-Temperature Field Dry-Well

  • Temperature Range: 35 °C to 350 °C
  • Stability: ±0.05 °C or better
  • Uniformity:
    • 0.1 °C in small-diameter wells
    • 0.4 °C in largest-diameter wells
  • Speed: Reaches max temperature in 12 minutes
  • Size: Weighs only 6 lbs, easily portable with one hand
  • Display Accuracy: ±0.5 °C

For improved calibration accuracy, use an external thermometer alongside the built-in display.

Insert Options:

Three removable inserts available to accommodate various probe sizes.

Why Choose the 9103 or 9140?

Model Temperature Range Stability Display Accuracy Key Benefits
9103 –25 °C to 110+ °C ±0.02 °C ±0.25 °C True sub-ambient performance without freezer
9140 35 °C to 350 °C ±0.05 °C ±0.5 °C Light, fast, and ideal for field portability

Both models are:

  • Reliable for industrial and lab environments
  • Versatile with multiple insert options
  • Backed by Fluke’s proven calibration technology

Key Features

  • Accuracy to ±0.25°C and comes with an RS-232 interface.
  • The 9103 covers below-ambient temperatures as low as –25 °C. The 9103 is stable to ±0.02 °C
  • The 9140 has a temperature range of 35 °C to 350 °C. The 9140 has a stability of ±0.05 °C.
  • Features designed with user convenience and productivity in mind.

Specifications: Fluke Calibration 9103/9140 Field Dry-Well

Specifications 9103 9140
Range –25°C to 140°C
(–13°F to 284°F)
at 23°C ambient
35°C to 350°C
(95°F to 662°F)
Accuracy ±0.25°C (holes greater than 1/4" [6.35mm]: ±1°C) ±0.5°C (holes greater than 1/4" [6.35mm]: ±1°C)
Stability ±0.02°C at –25°C
±0.04°C at 140°C
±0.03°C at 50°C
±0.05°C at 350°C
Well-to-well uniformity ±0.1°C between similarly sized wells ±0.1°C with similarly sized wells
Heating times 18 minutes from ambient to 140°C 12 minutes from ambient to 350°C
Cooling times 20 minutes from ambient to –25°C 15 minutes from 350°C to 100°C
Stabilization time 7 minutes 7 minutes
Immersion depth 124 mm (4.875 in) 124 mm (4.875 in)
Inserts Insert A, B, C, or D included (specify when ordering)
Outside insert dimensions 31.8 mm dia. x 124 mm (1.25 x 4.88 in)
Computer interface RS-232 included with free Interface-it software (Model 9930)
Power 115 V AC (±10%), 1.3 A or 230 V AC (±10%), 0.7 A, switchable, 50/60 Hz, 150 W 115 V AC (±10%), 4.4 A or 230 V AC (±10%), 2.2 A, switchable, 50/60 Hz, 500 W
Size (W x H x D) 143 x 261 x 245 mm
(5.63 x 10.25 x 9.63 in)
152 x 86 x 197 mm
(6 x 3.375 x 7.75 in)
Weight 5.7 kg (12 lb) 2.7 kg (6 lb)
NIST-traceable certificate Data at –25°C, 0°C, 25°C, 50°C, 75°C, 100°C, and 140° Data at 50°C, 100°C, 150°C, 200°C, 250°C, 300°C, and 350°C

Accessories: Fluke Calibration 9103/9140 Field Dry-Well

Calibration inserts (10)

  • 3103-1 | Insert, Blank no holes, 9011/9103
  • 3103-2 | Insert, "A" w/ misc holes, 9011/9103
  • 3103-3 | Insert, "B" w/ cmprsn hls, 9011/9103
  • 3103-4 | Insert, "C" w/ 6 .25" holes, 9011/9103
  • 3103-6 | Insert, "D", 9011/9103
  • 3140-1 | Insert, 9140 no holes - Blank, ring
  • 3140-2 | Insert, 9140 "A" w/ misc holes, ring
  • 3140-3 | Insert, 9140 "B" w/ cmprsn hls, ring
  • 3140-4 | Insert, 9140 "C" w/ 6 0.25" holes, ring
  • 3140-6 | Insert, 9140 "D" w/ misc holes, ring

Cases and holsters (2)

  • 9316 | Rugged Carrying Case : 9103
  • 9308 |Rugged Carrying Case

Adapters and cables (1)

  • HART DRYWELL CABLE | An interface cable kit that includes a null modem to connect the Fluke 754 with Fluke Calibration dry-wells and Micro-Baths to automate

Accessories: Fluke Calibration 9103/9140 Field Dry-Well

Calibration inserts (10)

  • 3103-1 | Insert, Blank no holes, 9011/9103
  • 3103-2 | Insert, "A" w/ misc holes, 9011/9103
  • 3103-3 | Insert, "B" w/ cmprsn hls, 9011/9103
  • 3103-4 | Insert, "C" w/ 6 .25" holes, 9011/9103
  • 3103-6 | Insert, "D", 9011/9103
  • 3140-1 | Insert, 9140 no holes - Blank, ring
  • 3140-2 | Insert, 9140 "A" w/ misc holes, ring
  • 3140-3 | Insert, 9140 "B" w/ cmprsn hls, ring
  • 3140-4 | Insert, 9140 "C" w/ 6 0.25" holes, ring
  • 3140-6 | Insert, 9140 "D" w/ misc holes, ring

Cases and holsters (2)

  • 9316 | Rugged Carrying Case : 9103
  • 9308 |Rugged Carrying Case

Adapters and cables (1)

  • HART DRYWELL CABLE | An interface cable kit that includes a null modem to connect the Fluke 754 with Fluke Calibration dry-wells and Micro-Baths to automate

Product overview: Fluke Calibration 9103/9140 Field Dry-Well

Portable, fast, and accurate temperature sources for on-site calibration

Exceptional Performance in a Compact Design

The Fluke 9103 and 9140 Field Dry-Wells outperform the competition in nearly every category—performance, size, weight, ease of use, calibration simplicity, software integration, and price.

Each unit features:

  • Adjustable heating and cooling rates via the front panel
  • Thermal switch actuation testing
  • Multiple-hole inserts for compatibility with a wide range of probe sizes

Fast Calibration with Minimal Downtime

  • Units are easy to calibrate without opening the case, reducing maintenance costs and downtime
  • All units include a NIST-traceable calibration certificate at no additional charge
  • Factory-tested for accuracy and reliability before shipment

Software Integration

Fluke’s Interface-it software supports:

  • Set-point and ramp rate control
  • Real-time temperature logging
  • Electronic strip chart creation
  • Thermal switch test automation with data collection
  • Windows-based interface with intuitive graphical controls

Whether you need basic control or full automation, Fluke has a software solution ready.

Fluke 9103 – Low-Temperature Field Dry-Well

  • Temperature Range: Down to –25 °C (actual, not below ambient)
  • Stability: ±0.02 °C
  • Display Accuracy: ±0.25 °C across full range
  • Speed:
    • Reaches 0 °C in 8 minutes
    • Reaches 100 °C in 6 minutes

Key Advantage:

Many competitors advertise –45 °C below ambient, which only reaches around –20 °C. The 9103 delivers a true –25 °C in standard room conditions—no walk-in freezer required.

Insert Options:

Choose from four removable inserts to suit your calibration needs:

  • Insert A: One well each from 1/16” to 1/2”
  • Insert B: Two wells each of 3/8”, 1/4”, and 3/16” (ideal for comparison calibrations)
  • Insert C: Six 1/4” wells for multiple probe calibrations
  • Insert D: Three pairs of metric-sized wells

Fluke 9140 – Mid-Temperature Field Dry-Well

  • Temperature Range: 35 °C to 350 °C
  • Stability: ±0.05 °C or better
  • Uniformity:
    • 0.1 °C in small-diameter wells
    • 0.4 °C in largest-diameter wells
  • Speed: Reaches max temperature in 12 minutes
  • Size: Weighs only 6 lbs, easily portable with one hand
  • Display Accuracy: ±0.5 °C

For improved calibration accuracy, use an external thermometer alongside the built-in display.

Insert Options:

Three removable inserts available to accommodate various probe sizes.

Why Choose the 9103 or 9140?

Model Temperature Range Stability Display Accuracy Key Benefits
9103 –25 °C to 110+ °C ±0.02 °C ±0.25 °C True sub-ambient performance without freezer
9140 35 °C to 350 °C ±0.05 °C ±0.5 °C Light, fast, and ideal for field portability

Both models are:

  • Reliable for industrial and lab environments
  • Versatile with multiple insert options
  • Backed by Fluke’s proven calibration technology

Key Features

  • Accuracy to ±0.25°C and comes with an RS-232 interface.
  • The 9103 covers below-ambient temperatures as low as –25 °C. The 9103 is stable to ±0.02 °C
  • The 9140 has a temperature range of 35 °C to 350 °C. The 9140 has a stability of ±0.05 °C.
  • Features designed with user convenience and productivity in mind.

Specifications: Fluke Calibration 9103/9140 Field Dry-Well

Specifications 9103 9140
Range –25°C to 140°C
(–13°F to 284°F)
at 23°C ambient
35°C to 350°C
(95°F to 662°F)
Accuracy ±0.25°C (holes greater than 1/4" [6.35mm]: ±1°C) ±0.5°C (holes greater than 1/4" [6.35mm]: ±1°C)
Stability ±0.02°C at –25°C
±0.04°C at 140°C
±0.03°C at 50°C
±0.05°C at 350°C
Well-to-well uniformity ±0.1°C between similarly sized wells ±0.1°C with similarly sized wells
Heating times 18 minutes from ambient to 140°C 12 minutes from ambient to 350°C
Cooling times 20 minutes from ambient to –25°C 15 minutes from 350°C to 100°C
Stabilization time 7 minutes 7 minutes
Immersion depth 124 mm (4.875 in) 124 mm (4.875 in)
Inserts Insert A, B, C, or D included (specify when ordering)
Outside insert dimensions 31.8 mm dia. x 124 mm (1.25 x 4.88 in)
Computer interface RS-232 included with free Interface-it software (Model 9930)
Power 115 V AC (±10%), 1.3 A or 230 V AC (±10%), 0.7 A, switchable, 50/60 Hz, 150 W 115 V AC (±10%), 4.4 A or 230 V AC (±10%), 2.2 A, switchable, 50/60 Hz, 500 W
Size (W x H x D) 143 x 261 x 245 mm
(5.63 x 10.25 x 9.63 in)
152 x 86 x 197 mm
(6 x 3.375 x 7.75 in)
Weight 5.7 kg (12 lb) 2.7 kg (6 lb)
NIST-traceable certificate Data at –25°C, 0°C, 25°C, 50°C, 75°C, 100°C, and 140° Data at 50°C, 100°C, 150°C, 200°C, 250°C, 300°C, and 350°C

Accessories: Fluke Calibration 9103/9140 Field Dry-Well

Calibration inserts (10)

  • 3103-1 | Insert, Blank no holes, 9011/9103
  • 3103-2 | Insert, "A" w/ misc holes, 9011/9103
  • 3103-3 | Insert, "B" w/ cmprsn hls, 9011/9103
  • 3103-4 | Insert, "C" w/ 6 .25" holes, 9011/9103
  • 3103-6 | Insert, "D", 9011/9103
  • 3140-1 | Insert, 9140 no holes - Blank, ring
  • 3140-2 | Insert, 9140 "A" w/ misc holes, ring
  • 3140-3 | Insert, 9140 "B" w/ cmprsn hls, ring
  • 3140-4 | Insert, 9140 "C" w/ 6 0.25" holes, ring
  • 3140-6 | Insert, 9140 "D" w/ misc holes, ring

Cases and holsters (2)

  • 9316 | Rugged Carrying Case : 9103
  • 9308 |Rugged Carrying Case

Adapters and cables (1)

  • HART DRYWELL CABLE | An interface cable kit that includes a null modem to connect the Fluke 754 with Fluke Calibration dry-wells and Micro-Baths to automate

Accessories: Fluke Calibration 9103/9140 Field Dry-Well

Calibration inserts (10)

  • 3103-1 | Insert, Blank no holes, 9011/9103
  • 3103-2 | Insert, "A" w/ misc holes, 9011/9103
  • 3103-3 | Insert, "B" w/ cmprsn hls, 9011/9103
  • 3103-4 | Insert, "C" w/ 6 .25" holes, 9011/9103
  • 3103-6 | Insert, "D", 9011/9103
  • 3140-1 | Insert, 9140 no holes - Blank, ring
  • 3140-2 | Insert, 9140 "A" w/ misc holes, ring
  • 3140-3 | Insert, 9140 "B" w/ cmprsn hls, ring
  • 3140-4 | Insert, 9140 "C" w/ 6 0.25" holes, ring
  • 3140-6 | Insert, 9140 "D" w/ misc holes, ring

Cases and holsters (2)

  • 9316 | Rugged Carrying Case : 9103
  • 9308 |Rugged Carrying Case

Adapters and cables (1)

  • HART DRYWELL CABLE | An interface cable kit that includes a null modem to connect the Fluke 754 with Fluke Calibration dry-wells and Micro-Baths to automate
seller

Sellers

Connect your real buyer on Tools Bangaldesh where visit the maximum customer for Tools In Bangladesh.

e-marketplace

e-Marketplace

Tools Bangladesh is a Trustworthy e-Marketplace in Bangladesh. Connect buyer and seller on the trade fair.

growth

Buyers

Get the reliable and authentic Tools at the best price in Bangladesh with on time delivery entire Bangladesh.