GENNECT ONE is a free PC software for Windows operating systems that lets you log data in real-time, import data and files, configure instrument settings, export native data as a CSV file and create reports with select Hioki measuring instruments.
Remote measurement is also possible by connecting to the GENNECT Cloud.

GENNECT ONE Special WEB site

A special website introducing the charm of GENNECT ONE has been released.
We will continue to provide useful information such as functions, application examples, and technical information in the field.

Key Features

  • Connect measuring instruments to a PC via a LAN cable
  • Acquire measurement values from multiple measuring instruments at regular intervals and display them on a graph in real time. (*1)
  • Lay out measurement values on the image and able to check graphically (*1)
  • Operate measuring instruments connected via LAN from a PC (*2)
  • Automatically transfer files saved on a LAN-connected measuring instrument to a PC (*3)
  • List MAX, MIN and AVG values (Display time of MAX & MIN data)
  • Real-time calculation of measurement values of arbitrary measurement items (calculation between channels)
  • Automatically output measurement data to daily/weekly/monthly report or CSV file
  • Enable remote measurement by connecting to GENNECT Cloud

Enable remote measurement by connecting to GENNECT Cloud

You can connect GENNECT One to GENNECT Cloud, the cloud service designed specifically for Hioki's GENNECT series. Users can access GENNECT One via GENNECT Cloud anytime, from anywhere.

Integration with GENNECT Cloud

Functions - Upload measurement data on the local PC to the cloud for sharing and management
- Receive measurement values from remotely connected instruments, retrieve instrument data files, or control instruments remotely(*1) (Remote measurement mode)
- Upload threshold information of battery testers BT3554, BT3554-01, BT3554-50 and profile information of BT3554-50 to the cloud for sharing and management (*2)

(*1) Remote instrument control is only available with the Standard/Pro plans of GENNECT Cloud.
(*2) Available only with GENNECT Cloud's Standard/Pro plans.
Storage size Trial: 512MB, Free: 5GB, Standard: 50GB, Pro: 500GB
Supported models
(Remote measurement mode)
PQ3100, PQ3198, PW3335, PW3336, PW3337, PW3360, PW3365, PW3390, PW6001, PW8001, LR8410, LR8416, LR8450, LR8450-01, MR6000

(*1) LR8410 and LR8416 do not support remote control via cloud.
(*2) PW3335, PW3336, PW3337, PW3390, and PW6001 do not support data file downloading in remote measurement mode.
Max. number of units that can be connected
(Remote measurement mode)
Trial: 1 unit, Free: 3 units, Standard: 8 units, Pro: 8 units
Max. number of channels selectable per unit
(Remote measurement mode)
Trial: 10, Free: 30, Standard: 30, Pro: 100

Logging

Functions • Generate monitor, graph, and list displays of measured values from LAN-connected instruments in real time. *
• Real-time calculation of measurement values of arbitrary measurement items (calculation between channels)
• Automatically output measurement data to daily/weekly/monthly report or CSV file

* Acquire measured values (current values) displayed on instruments at a set interval (as short as 1 sec.) using the computer’s timer.
* Max. 32 items when simultaneously displaying graphs
Logging intervals 1, 2, 5, 10, 30 sec.
1, 2, 5, 10, 30 min.
1 hour
Measured parameters • PW8001, PW6001, PW3390: Basic Measurement items, Harmonic measurement items (Instantaneous value per interval)
• PW3335, PW3336, PW3337: Basic Measurement items (Instantaneous value per interval)
• PQ3100, PQ3198, PW3365, PW3360: Voltage, Current, Power (Instantaneous value per interval, MAX, MIN, AVE values between intervals)
• LR8400, LR8401, LR8402, LR8410, LR8450, LR8450-01, MR6000: Various measurement items such as Temperature, Analog input, etc. (Instantaneous value per interval)
• Calculation between channels (up to 16 items)
Number of items able to monitor and log Max. 512 items + 16 items (calculation between channels)
Recording time Recording time: Continuous measurement,set time
File segmentation: 1 day, 1 hour
Logging stops when the storage capacity of the PC is below 512 MB
Max. number of connections 30 units

Dashboard

Functions • Monitor measured values in real time from LAN-connected instruments.*
• Display alarms in real time when a measured value exceeds a threshold.*
• Display measured values on a user-selected image.
• Real-time calculation of measurement values of arbitrary measurement items (calculation between channels)
• Automatically output measurement data to daily/weekly/monthly report or CSV file

* Acquire measured values (current values) displayed on instruments at a set interval (as short as 1 sec.) according to the computer’s timer.
Monitoring intervals 1, 2, 5, 10, 30 sec.
1, 2, 5, 10, 30 min.
1 hour
Measured parameters • PW8001, PW6001, PW3390: Basic Measurement items, Harmonic measurement items (Instantaneous value per interval)
• PW3335, PW3336, PW3337: Basic Measurement items (Instantaneous value per interval)
• PQ3100, PQ3198, PW3365, PW3360: Voltage, Current, Power (Instantaneous value per interval, MAX, MIN, AVE values between intervals)
• LR8400, LR8401, LR8402, LR8410, LR8450, LR8450-01, MR6000: Various measurement items such as Temperature, Analog input, etc. (Instantaneous value per interval)
• Calculation between channels (up to 16 items)
Number of stored parameters Max. 512 items + 16 items (calculation between channels)
Recording time Recording time: Continuous measurement
File segmentation: 1 day, 1 hour
Logging stops when the storage capacity of the PC is below 512 MB
Max. number of connections 30 units

Remote control

Functions Control LAN-connected instruments from a computer
Number of simultaneous operation 30 unit at a time

File transfer (Manual)

Interface LAN, USB (USB only for BT3554-50, BT3554, 3554)
Functions Acquire files stored in LAN-connected instruments from a PC
The BT3554-50 series can be acquired via USB.
Compatible instruments PQ3100, PQ3198, PW3360, PW3365, PW3390, PW6001, PW8001,
LR8400, LR8401, LR8402, LR8410, LR8416, LR8450, LR8450-01, MR6000, BT3554-50, BT3554, 3554
Number of simultaneous operations 1 unit at a time

File transfer (Automatic)

Functions Automatically send files saved by LAN-connected instruments to a computer.
Compatible instruments PQ3100, PQ3198, PW3360, PW3365, PW8001, LR8400, LR8401, LR8402, LR8410, LR8416, LR8450, LR8450-01, MR6000
Max. number of connections 15 units

Other functions

Files loading • Data file obtained by GENNECT Cross for iOS/Android
*Logging, General Measurement, image and battery formats only
*No direct Bluetooth® connection is possible, please use the smartphone app for Bluetooth® data collection
• Data file obtained by GENNECT Remote
• Measurement data folder (PQ3100, PQ3198, PW3360, PW3365)
• Measurement data file (LR8400 series, LR8410, LR8416, LR8450, MR6000, LR5000 series, PW3390, PW6001, PW8001)
Instrument clock
synchronization
Set the clocks of measuring instruments connected via LAN to the PC (manual, automatic)
CSV output Logging data, time-series measurement data, waveform files of instruments supporting time-series viewer, data files acquired by GENNECT Cross (standard measurement, battery)
Report creation PDF, Word and Excel formats

System requirements

Supported operating systems Windows 10 (32bit / 64bit)
Windows 11
Software environment Microsoft .NET Framework 4.6.2 or later
CPU Clock speed: 2 GHz or greater
RAM 4 GB or more
Display 1366 × 768 or better resolution
Hard drive 1 GB or more available space

GENNECT ONE is a free PC software for Windows operating systems that lets you log data in real-time, import data and files, configure instrument settings, export native data as a CSV file and create reports with select Hioki measuring instruments.
Remote measurement is also possible by connecting to the GENNECT Cloud.

GENNECT ONE Special WEB site

A special website introducing the charm of GENNECT ONE has been released.
We will continue to provide useful information such as functions, application examples, and technical information in the field.

Key Features

  • Connect measuring instruments to a PC via a LAN cable
  • Acquire measurement values from multiple measuring instruments at regular intervals and display them on a graph in real time. (*1)
  • Lay out measurement values on the image and able to check graphically (*1)
  • Operate measuring instruments connected via LAN from a PC (*2)
  • Automatically transfer files saved on a LAN-connected measuring instrument to a PC (*3)
  • List MAX, MIN and AVG values (Display time of MAX & MIN data)
  • Real-time calculation of measurement values of arbitrary measurement items (calculation between channels)
  • Automatically output measurement data to daily/weekly/monthly report or CSV file
  • Enable remote measurement by connecting to GENNECT Cloud

Enable remote measurement by connecting to GENNECT Cloud

You can connect GENNECT One to GENNECT Cloud, the cloud service designed specifically for Hioki's GENNECT series. Users can access GENNECT One via GENNECT Cloud anytime, from anywhere.

Integration with GENNECT Cloud

Functions - Upload measurement data on the local PC to the cloud for sharing and management
- Receive measurement values from remotely connected instruments, retrieve instrument data files, or control instruments remotely(*1) (Remote measurement mode)
- Upload threshold information of battery testers BT3554, BT3554-01, BT3554-50 and profile information of BT3554-50 to the cloud for sharing and management (*2)

(*1) Remote instrument control is only available with the Standard/Pro plans of GENNECT Cloud.
(*2) Available only with GENNECT Cloud's Standard/Pro plans.
Storage size Trial: 512MB, Free: 5GB, Standard: 50GB, Pro: 500GB
Supported models
(Remote measurement mode)
PQ3100, PQ3198, PW3335, PW3336, PW3337, PW3360, PW3365, PW3390, PW6001, PW8001, LR8410, LR8416, LR8450, LR8450-01, MR6000

(*1) LR8410 and LR8416 do not support remote control via cloud.
(*2) PW3335, PW3336, PW3337, PW3390, and PW6001 do not support data file downloading in remote measurement mode.
Max. number of units that can be connected
(Remote measurement mode)
Trial: 1 unit, Free: 3 units, Standard: 8 units, Pro: 8 units
Max. number of channels selectable per unit
(Remote measurement mode)
Trial: 10, Free: 30, Standard: 30, Pro: 100

Logging

Functions • Generate monitor, graph, and list displays of measured values from LAN-connected instruments in real time. *
• Real-time calculation of measurement values of arbitrary measurement items (calculation between channels)
• Automatically output measurement data to daily/weekly/monthly report or CSV file

* Acquire measured values (current values) displayed on instruments at a set interval (as short as 1 sec.) using the computer’s timer.
* Max. 32 items when simultaneously displaying graphs
Logging intervals 1, 2, 5, 10, 30 sec.
1, 2, 5, 10, 30 min.
1 hour
Measured parameters • PW8001, PW6001, PW3390: Basic Measurement items, Harmonic measurement items (Instantaneous value per interval)
• PW3335, PW3336, PW3337: Basic Measurement items (Instantaneous value per interval)
• PQ3100, PQ3198, PW3365, PW3360: Voltage, Current, Power (Instantaneous value per interval, MAX, MIN, AVE values between intervals)
• LR8400, LR8401, LR8402, LR8410, LR8450, LR8450-01, MR6000: Various measurement items such as Temperature, Analog input, etc. (Instantaneous value per interval)
• Calculation between channels (up to 16 items)
Number of items able to monitor and log Max. 512 items + 16 items (calculation between channels)
Recording time Recording time: Continuous measurement,set time
File segmentation: 1 day, 1 hour
Logging stops when the storage capacity of the PC is below 512 MB
Max. number of connections 30 units

Dashboard

Functions • Monitor measured values in real time from LAN-connected instruments.*
• Display alarms in real time when a measured value exceeds a threshold.*
• Display measured values on a user-selected image.
• Real-time calculation of measurement values of arbitrary measurement items (calculation between channels)
• Automatically output measurement data to daily/weekly/monthly report or CSV file

* Acquire measured values (current values) displayed on instruments at a set interval (as short as 1 sec.) according to the computer’s timer.
Monitoring intervals 1, 2, 5, 10, 30 sec.
1, 2, 5, 10, 30 min.
1 hour
Measured parameters • PW8001, PW6001, PW3390: Basic Measurement items, Harmonic measurement items (Instantaneous value per interval)
• PW3335, PW3336, PW3337: Basic Measurement items (Instantaneous value per interval)
• PQ3100, PQ3198, PW3365, PW3360: Voltage, Current, Power (Instantaneous value per interval, MAX, MIN, AVE values between intervals)
• LR8400, LR8401, LR8402, LR8410, LR8450, LR8450-01, MR6000: Various measurement items such as Temperature, Analog input, etc. (Instantaneous value per interval)
• Calculation between channels (up to 16 items)
Number of stored parameters Max. 512 items + 16 items (calculation between channels)
Recording time Recording time: Continuous measurement
File segmentation: 1 day, 1 hour
Logging stops when the storage capacity of the PC is below 512 MB
Max. number of connections 30 units

Remote control

Functions Control LAN-connected instruments from a computer
Number of simultaneous operation 30 unit at a time

File transfer (Manual)

Interface LAN, USB (USB only for BT3554-50, BT3554, 3554)
Functions Acquire files stored in LAN-connected instruments from a PC
The BT3554-50 series can be acquired via USB.
Compatible instruments PQ3100, PQ3198, PW3360, PW3365, PW3390, PW6001, PW8001,
LR8400, LR8401, LR8402, LR8410, LR8416, LR8450, LR8450-01, MR6000, BT3554-50, BT3554, 3554
Number of simultaneous operations 1 unit at a time

File transfer (Automatic)

Functions Automatically send files saved by LAN-connected instruments to a computer.
Compatible instruments PQ3100, PQ3198, PW3360, PW3365, PW8001, LR8400, LR8401, LR8402, LR8410, LR8416, LR8450, LR8450-01, MR6000
Max. number of connections 15 units

Other functions

Files loading • Data file obtained by GENNECT Cross for iOS/Android
*Logging, General Measurement, image and battery formats only
*No direct Bluetooth® connection is possible, please use the smartphone app for Bluetooth® data collection
• Data file obtained by GENNECT Remote
• Measurement data folder (PQ3100, PQ3198, PW3360, PW3365)
• Measurement data file (LR8400 series, LR8410, LR8416, LR8450, MR6000, LR5000 series, PW3390, PW6001, PW8001)
Instrument clock
synchronization
Set the clocks of measuring instruments connected via LAN to the PC (manual, automatic)
CSV output Logging data, time-series measurement data, waveform files of instruments supporting time-series viewer, data files acquired by GENNECT Cross (standard measurement, battery)
Report creation PDF, Word and Excel formats

System requirements

Supported operating systems Windows 10 (32bit / 64bit)
Windows 11
Software environment Microsoft .NET Framework 4.6.2 or later
CPU Clock speed: 2 GHz or greater
RAM 4 GB or more
Display 1366 × 768 or better resolution
Hard drive 1 GB or more available space

We'd love to hear from you
+8801965656380
Local: +8801965656380
User

Real people, here to help you.

Get Connected

Join the community and find out what we're up to, experience live product releases, webinars and more!

seller

Sellers

Connect your real buyer on Tools Bangaldesh where visit the maximum customer for Tools In Bangladesh.

e-marketplace

e-Marketplace

Tools Bangladesh is a Trustworthy e-Marketplace in Bangladesh. Connect buyer and seller on the trade fair.

growth

Buyers

Get the reliable and authentic Tools at the best price in Bangladesh with on time delivery entire Bangladesh.