Shop : Tools Bangladesh
Product ID : 4009
Brand : Fluke
Availability : In Stock (1)
Price BDT : Ask for Price
Reviews :
Share :
Request Quote
  • Customer Support

    +8801965656380
  • Cash One Delivery

    Pay after getting the product on hand
  • Warranty

    1 Year warranty by manufacturer
  • Secured Payment Method

    Your cart is always secure to shop
  • Easy Return Policy

    24 hours return without physical defect.

Product overview: 8558A 8.5 Digit Multimeter

Accurate data, delivered amazingly fast


Shorter test time on the 8588A/8558A high-speed digital platform enables you to increase throughput, improve yield and realize a greater return on your investment. The 8588A/8558A digitizes to memory at 200 nanoseconds per reading and delivers 4.5 digit data to a PC via USB, Ethernet and GPIB at 100,000 readings per second. Fast, high resolution data capture gives you the quantity and quality of information you need to make timely, correct decisions affecting system throughput and efficiency.

  • 0 ns to 100 s aperture setting allows industry’s widest flexibility to control data capture window
  • Reading speed: 1 reading /s @ 8.5 digits to 100,000 reading /s @ 4.5 digits
  • Data transfer from memory to PC: up to 500,000 readings /s in binary format through USB, up to 200,000 through Ethernet and GPIB

Debug and perfect your device under test


The 8558A features a 5 mega-sample digitizing rate with up to 20 MHz analog bandwidth, making it the first and only instrument on the market that can characterize extremely low level transient signals at 18-bit resolution. This capability makes it easier to debug designs, uncover anomalies and perfect your devices under test for use in real life environments.

  • Voltage sensitivity to hundreds of nV and current sensitivity to hundreds of pA allows you uncover ultra-low level transient signals
  • Up to 20 MHz bandwidth for voltage and 4 MHz for current retains high bandwidth content of the signal measured
  • 18-bit SAR analog-to-digital converter that achieves 5 mega-samples per second
  • 5 mega-samples per second sample rate, into buffer, for capturing complex, fast changing waveforms
  • 15 million readings memory allows large amount of data storage eliminating the
  • immediate need to transfer data to a PC
  • Graphical waveform display enables real-time visualization of complex waveforms, increased productivity with faster access to results and answers

Fast, reliable and accurate system compatibility


Inserting a new instrument into a tightly synchronized system can create overhead and incompatibility. The 8558A’s digital platform includes common connectivity interfaces plus precise triggering that lets it digitize, integrate and transfer data to anywhere in the system for analysis, with minimal obstruction and the highest reliability.

  • GPIB, USBTMC, Ethernet allows industry standard selection of remote interface
  • USB thumb drive enable quick and easy data transfer to PC in .csv format
  • SCPI compliant commands with 8505A and 3458A emulation mode simplifies and accelerates system upgrade process to 8588A/8558A
  • Fully supports MET/CAL calibration procedures library that commands the Fluke 8508A
  • IVI Driver for industry standard control of DMM on 8558A/8588A
  • Trigger Mechanisms: External BNC Trigger Trig In and Trig Out, Edge or level trigger, Timer trigger, Epoch trigger, Line trigger
  • Less than 100 ns trigger latency with external BNC trigger for digitize voltage and current

Key Features

  • 5 mega-samples-per-second high resolution digitizing, providing exceptional speed and accuracy.
  • Intuitive user interface on a color display for easy data viewing in various formats including trend plots, waveforms, FFT, histogram and statistics.
  • Direct digitizing capability with a minimum of 100,000 readings per second at 4.5 digits across GPIB, USBTMC, or Ethernet.
  • Onboard data memory that can hold up to 15 million readings.
  • Programmable front/rear electronic switch for immediate ratio results through a single remote command, and several USB ports for quick and easy data download to a flash drive.

Specifications: 8558A 8.5 Digit Multimeter

Key feature and specification comparison 8558A 8588A
DC voltage 100 mV – 1000 V 100 mV – 1000 V
AC voltage 10 mV – 1000 V, 1 Hz – 10 MHz 10 mV – 1000 V, 1 Hz – 10 MHz
Resistance, LoI, HV 1 Ω - 10 GΩ 1 Ω - 10 GΩ
DC current 10 uA – 2 A 10 uA – 30 A
AC current 10 uA – 2A, 1 Hz to 100 kHz 10 uA – 30 A, 1 Hz to 100 kHz
Digitize V 100 mV - 1000 V, 5 MSamples/s, up to 20 MHz BW 100 mV - 1000 V, 5 MSamples/s, up to 20 MHz BW
Digitize I 10 uA - 2 A, 5 MSamples/s,
up to 4 MHz BW
10 uA - 30 A, 5 MSamples/s, up to 4 MHz BW
Frequency (V, I, BNC) 1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz 1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz
Temperature PRT / Thermocouple (ext CJC) PRT / Thermocouple (ext CJC)
Capacitance No 1 nF – 100 mF
RF power No R&S NRP Series
Ext. dc current and ac current No A40B current shunt and other shunts
Graphical display Yes Yes
Visual Connection Management ® Yes Yes
Programmable front/rear input switching Yes Yes
Ratio difference, deviation - ohms, voltage Yes Yes
External 10 MHz ref clock, 50 Î©/Hi-Z Yes Yes
A40B and other shunt asset management No Yes
GPIB 488.2, Ethernet, USB TMC Yes Yes
SCPI command compatibility Yes Yes
3458A emulation, 8508A emulation Yes Yes
Memory 15 million 15 million
Level and other trigger Yes Yes
FFT onboard No Yes
Reading rates: 5 MS/s into memory, bus: 100 kS/s at 4.5 digits, 1 rdg/s at 8.5 digits Yes Yes

 

Function 8558A uX/X of reading + uX/X of range  8588A uX/X of reading + uX/X of range 
95% 99% 95% 99%
DC voltage 10 V relative 4.0 + 0.06 5.2 + 0.08 2.7 + 0.05 3.5 + 0.06
absolute 4.1 + 0.06 5.3 + 0.08 2.8 + 0.05 3.6 + 0.06
AC voltage 10 V, 1 kHz relative 80 + 10 103 + 13 60 + 5 77 + 6.5
absolute 90 + 10 116 + 13 64 + 5 83 + 6.5
Resistance 10 kΩ relative 10 + 0.6 13 + 0.7 7 + 0.5 9 + 0.6
absolute 10.3 + 0.6 13.3 + 0.7 7.2 + 0.5 9.2 + 0.6
DC current 1 mA relative 9 + 5 12 + 6 6.5 + 4 8.4 + 5
absolute 9.8 + 5 13 + 6 7.6 + 4 10 + 5
AC current 1 mA, 1 kHz relative 300 + 100 387 + 129 250 + 50 323 + 65
absolute 310 + 100 400 + 129 260 + 50 335 + 65
Frequency 1 kHz relative N/A N/A 0.5 0.5
Temperature PRT 100 Ω relative ± 5 mK ± 5 mK ± 5 mK ± 5 mK
Capacitance 1 uF relative N/A N/A 400 + 100 516 + 129
absolute N/A N/A 406 + 100 523 + 129

95% 1 year relative specification. Fluke Calibration guarantees to 99% confidence interval k=2.58. For 99%, multiply by (2.58/2)

Looking for lower specs? See our other benchtop multimeters:

Bench Multimeter Selection Guide
Model Resolution Accuracy Application
8588A 8.5 2.7 µV/V 95% confidence level, 1 year relative accuracy Metrology
8558A 8.5 4.0 µV/V 95% confidence level, 1 year relative accuracy High-Speed Automation
8845A/8846A 6.5 Basic V dc accuracy of up to 0.0024 % Bench
8808A 5.5 Basic V dc accuracy of 0.015 % Bench

Accessories: 8558A 8.5 Digit Multimeter

Rack mounts and hardware (2)

  • Y8588 | Rack Mount Kit (2U – 3.5 in)
  • Y8588S | Slide Rack Mount Kit

Test leads, probes and clips (2)

  • 8588A-LEAD | Comprehensive Measurement Lead Kit
  • 8588A-LEAD/THERMAL | Low Thermal Lead Kit

Other (3)

  • 8588A-SHORT | 4-Way Shorting PCB
  • 8588A-7000K | Cal Kit with 1 Gohm Standard and Connecting Leads
  • 96000SNS |Additional Power Sensor

Cases and holsters (1)

  • 8588A/CASE | Transit Case

Accessories: 8558A 8.5 Digit Multimeter

Rack mounts and hardware (2)

  • Y8588 | Rack Mount Kit (2U – 3.5 in)
  • Y8588S | Slide Rack Mount Kit

Test leads, probes and clips (2)

  • 8588A-LEAD | Comprehensive Measurement Lead Kit
  • 8588A-LEAD/THERMAL | Low Thermal Lead Kit

Other (3)

  • 8588A-SHORT | 4-Way Shorting PCB
  • 8588A-7000K | Cal Kit with 1 Gohm Standard and Connecting Leads
  • 96000SNS |Additional Power Sensor

Cases and holsters (1)

  • 8588A/CASE | Transit Case

Product overview: 8558A 8.5 Digit Multimeter

Accurate data, delivered amazingly fast


Shorter test time on the 8588A/8558A high-speed digital platform enables you to increase throughput, improve yield and realize a greater return on your investment. The 8588A/8558A digitizes to memory at 200 nanoseconds per reading and delivers 4.5 digit data to a PC via USB, Ethernet and GPIB at 100,000 readings per second. Fast, high resolution data capture gives you the quantity and quality of information you need to make timely, correct decisions affecting system throughput and efficiency.

  • 0 ns to 100 s aperture setting allows industry’s widest flexibility to control data capture window
  • Reading speed: 1 reading /s @ 8.5 digits to 100,000 reading /s @ 4.5 digits
  • Data transfer from memory to PC: up to 500,000 readings /s in binary format through USB, up to 200,000 through Ethernet and GPIB

Debug and perfect your device under test


The 8558A features a 5 mega-sample digitizing rate with up to 20 MHz analog bandwidth, making it the first and only instrument on the market that can characterize extremely low level transient signals at 18-bit resolution. This capability makes it easier to debug designs, uncover anomalies and perfect your devices under test for use in real life environments.

  • Voltage sensitivity to hundreds of nV and current sensitivity to hundreds of pA allows you uncover ultra-low level transient signals
  • Up to 20 MHz bandwidth for voltage and 4 MHz for current retains high bandwidth content of the signal measured
  • 18-bit SAR analog-to-digital converter that achieves 5 mega-samples per second
  • 5 mega-samples per second sample rate, into buffer, for capturing complex, fast changing waveforms
  • 15 million readings memory allows large amount of data storage eliminating the
  • immediate need to transfer data to a PC
  • Graphical waveform display enables real-time visualization of complex waveforms, increased productivity with faster access to results and answers

Fast, reliable and accurate system compatibility


Inserting a new instrument into a tightly synchronized system can create overhead and incompatibility. The 8558A’s digital platform includes common connectivity interfaces plus precise triggering that lets it digitize, integrate and transfer data to anywhere in the system for analysis, with minimal obstruction and the highest reliability.

  • GPIB, USBTMC, Ethernet allows industry standard selection of remote interface
  • USB thumb drive enable quick and easy data transfer to PC in .csv format
  • SCPI compliant commands with 8505A and 3458A emulation mode simplifies and accelerates system upgrade process to 8588A/8558A
  • Fully supports MET/CAL calibration procedures library that commands the Fluke 8508A
  • IVI Driver for industry standard control of DMM on 8558A/8588A
  • Trigger Mechanisms: External BNC Trigger Trig In and Trig Out, Edge or level trigger, Timer trigger, Epoch trigger, Line trigger
  • Less than 100 ns trigger latency with external BNC trigger for digitize voltage and current

Key Features

  • 5 mega-samples-per-second high resolution digitizing, providing exceptional speed and accuracy.
  • Intuitive user interface on a color display for easy data viewing in various formats including trend plots, waveforms, FFT, histogram and statistics.
  • Direct digitizing capability with a minimum of 100,000 readings per second at 4.5 digits across GPIB, USBTMC, or Ethernet.
  • Onboard data memory that can hold up to 15 million readings.
  • Programmable front/rear electronic switch for immediate ratio results through a single remote command, and several USB ports for quick and easy data download to a flash drive.

Specifications: 8558A 8.5 Digit Multimeter

Key feature and specification comparison 8558A 8588A
DC voltage 100 mV – 1000 V 100 mV – 1000 V
AC voltage 10 mV – 1000 V, 1 Hz – 10 MHz 10 mV – 1000 V, 1 Hz – 10 MHz
Resistance, LoI, HV 1 Ω - 10 GΩ 1 Ω - 10 GΩ
DC current 10 uA – 2 A 10 uA – 30 A
AC current 10 uA – 2A, 1 Hz to 100 kHz 10 uA – 30 A, 1 Hz to 100 kHz
Digitize V 100 mV - 1000 V, 5 MSamples/s, up to 20 MHz BW 100 mV - 1000 V, 5 MSamples/s, up to 20 MHz BW
Digitize I 10 uA - 2 A, 5 MSamples/s,
up to 4 MHz BW
10 uA - 30 A, 5 MSamples/s, up to 4 MHz BW
Frequency (V, I, BNC) 1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz 1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz
Temperature PRT / Thermocouple (ext CJC) PRT / Thermocouple (ext CJC)
Capacitance No 1 nF – 100 mF
RF power No R&S NRP Series
Ext. dc current and ac current No A40B current shunt and other shunts
Graphical display Yes Yes
Visual Connection Management ® Yes Yes
Programmable front/rear input switching Yes Yes
Ratio difference, deviation - ohms, voltage Yes Yes
External 10 MHz ref clock, 50 Î©/Hi-Z Yes Yes
A40B and other shunt asset management No Yes
GPIB 488.2, Ethernet, USB TMC Yes Yes
SCPI command compatibility Yes Yes
3458A emulation, 8508A emulation Yes Yes
Memory 15 million 15 million
Level and other trigger Yes Yes
FFT onboard No Yes
Reading rates: 5 MS/s into memory, bus: 100 kS/s at 4.5 digits, 1 rdg/s at 8.5 digits Yes Yes

 

Function 8558A uX/X of reading + uX/X of range  8588A uX/X of reading + uX/X of range 
95% 99% 95% 99%
DC voltage 10 V relative 4.0 + 0.06 5.2 + 0.08 2.7 + 0.05 3.5 + 0.06
absolute 4.1 + 0.06 5.3 + 0.08 2.8 + 0.05 3.6 + 0.06
AC voltage 10 V, 1 kHz relative 80 + 10 103 + 13 60 + 5 77 + 6.5
absolute 90 + 10 116 + 13 64 + 5 83 + 6.5
Resistance 10 kΩ relative 10 + 0.6 13 + 0.7 7 + 0.5 9 + 0.6
absolute 10.3 + 0.6 13.3 + 0.7 7.2 + 0.5 9.2 + 0.6
DC current 1 mA relative 9 + 5 12 + 6 6.5 + 4 8.4 + 5
absolute 9.8 + 5 13 + 6 7.6 + 4 10 + 5
AC current 1 mA, 1 kHz relative 300 + 100 387 + 129 250 + 50 323 + 65
absolute 310 + 100 400 + 129 260 + 50 335 + 65
Frequency 1 kHz relative N/A N/A 0.5 0.5
Temperature PRT 100 Ω relative ± 5 mK ± 5 mK ± 5 mK ± 5 mK
Capacitance 1 uF relative N/A N/A 400 + 100 516 + 129
absolute N/A N/A 406 + 100 523 + 129

95% 1 year relative specification. Fluke Calibration guarantees to 99% confidence interval k=2.58. For 99%, multiply by (2.58/2)

Looking for lower specs? See our other benchtop multimeters:

Bench Multimeter Selection Guide
Model Resolution Accuracy Application
8588A 8.5 2.7 µV/V 95% confidence level, 1 year relative accuracy Metrology
8558A 8.5 4.0 µV/V 95% confidence level, 1 year relative accuracy High-Speed Automation
8845A/8846A 6.5 Basic V dc accuracy of up to 0.0024 % Bench
8808A 5.5 Basic V dc accuracy of 0.015 % Bench

Accessories: 8558A 8.5 Digit Multimeter

Rack mounts and hardware (2)

  • Y8588 | Rack Mount Kit (2U – 3.5 in)
  • Y8588S | Slide Rack Mount Kit

Test leads, probes and clips (2)

  • 8588A-LEAD | Comprehensive Measurement Lead Kit
  • 8588A-LEAD/THERMAL | Low Thermal Lead Kit

Other (3)

  • 8588A-SHORT | 4-Way Shorting PCB
  • 8588A-7000K | Cal Kit with 1 Gohm Standard and Connecting Leads
  • 96000SNS |Additional Power Sensor

Cases and holsters (1)

  • 8588A/CASE | Transit Case

Accessories: 8558A 8.5 Digit Multimeter

Rack mounts and hardware (2)

  • Y8588 | Rack Mount Kit (2U – 3.5 in)
  • Y8588S | Slide Rack Mount Kit

Test leads, probes and clips (2)

  • 8588A-LEAD | Comprehensive Measurement Lead Kit
  • 8588A-LEAD/THERMAL | Low Thermal Lead Kit

Other (3)

  • 8588A-SHORT | 4-Way Shorting PCB
  • 8588A-7000K | Cal Kit with 1 Gohm Standard and Connecting Leads
  • 96000SNS |Additional Power Sensor

Cases and holsters (1)

  • 8588A/CASE | Transit Case
seller

Sellers

Connect your real buyer on Tools Bangaldesh where visit the maximum customer for Tools In Bangladesh.

e-marketplace

e-Marketplace

Tools Bangladesh is a Trustworthy e-Marketplace in Bangladesh. Connect buyer and seller on the trade fair.

growth

Buyers

Get the reliable and authentic Tools at the best price in Bangladesh with on time delivery entire Bangladesh.