Model: Fluke 1502A Tweener Thermometer Readouts
Fluke 1502A Tweener Thermometer ReadoutsOne of Fluke Calibration's best-selling products is the Tweener thermometer, and there’s a reason. No other company, not one, has a reference thermometer that comes close to the performance and features of the Tweener for anywhere near its price.
The best things about Tweener Thermometer Readouts that not only always provide accurate results but also the value of this Fluke product always spot on.
We Iconic Engineering offers the best and reliable Tweener Thermometer Readouts through Tools Bangladesh with affordable price. Keep it and get the best product that you are always looking for.
Key Features: 1502A, 1504 Tweener Thermometer Readouts
- Two Tweeners to choose from—reading PRTs or thermistors
- Best price/performance package
Specifications: 1502A, 1504 Tweener Thermometer Readouts
Specifications
|
1502A |
1504 |
| Temperature Range† |
−200 °C to 962 °C (−328 °F to 1764 °F) |
Any thermistor range |
| Resistance Range |
0 Ω to 400 Ω, auto-ranging |
0 Ω to 1 MΩ, auto-ranging |
| Probe |
Nominal RTPW: 10 Ω to 100 Ω
RTD, PRT, or SPRT |
Thermistors |
| Characterizations |
ITS-90 subranges 4, 6, 7, 8, 9, 10, and 11
IPTS-68: R0, a, d, a4, and c4
Callendar-Van Dusen: R0, a, d, and b |
Steinhart-Hart thermistor polynomial
Callendar-Van Dusen: R0, a, d, and b |
Resistance Accuracy
(ppm of reading) |
0 Ω to 20 Ω: 0.0005 Ω
20 Ω to 400 Ω: 25 ppm |
0 Ω to 5 KΩ: 0.5 Ω
5 KΩ to 200 KΩ: 100 ppm
200 KΩ to 1 MΩ: 300 ppm |
| Temperature Accuracy† |
±0.004 °C at −100 °C
±0.006 °C at 0 °C
±0.009 °C at 100 °C
±0.012 °C at 200 °C
±0.018 °C at 400 °C
±0.024 °C at 600 °C |
±0.002 °C at 0 °C
±0.002 °C at 25 °C
±0.004 °C at 50 °C
±0.010 °C at 75 °C
±0.020 °C at 100 °C
(Using 10 KΩ thermistor sensor, a=0.04. Does not include probe uncertainty or characterization errors.) |
| Operating Temperature Range |
16 °C to 30 °C |
13 °C to 33 °C |
| Resistance Resolution |
0 Ω to 20 Ω: 0.0001 Ω
20 Ω to 400 Ω: 0.001 Ω |
0 Ω to 10 KΩ: 0.01 Ω
10 KΩ to 100 KΩ: 0.1 Ω
100 KΩ to 1 MΩ: 1 Ω |
| Temperature Resolution |
0.001 °C |
0.0001 °C |
| Excitation Current |
0.5 and 1 mA, user selectable, 2 Hz |
2 and 10 µA, automatically selected |
| Measurement Period |
1 second |
| Digital Filter |
Exponential, 0 to 60 seconds time constant (user selectable) |
| Probe Connection |
4-wire with shield, 5-pin DIN connector |
| Communications |
RS-232 serial standard
IEEE-488 (GPIB) optional |
| Display |
8-digit, 7-segment, yellow-green LED; 0.5-inch-high characters |
| Power |
115 VAC (±10 %), 50/60 Hz, 1 A, nominal
230 VAC (±10 %), 50/60 Hz, 1 A, nominal, specify |
| Size (HxWxD) |
61 x 143 x 181mm (2.4 x 5.6 x 7.1 in) |
| Weight |
1.0 kg (2.2 lb.) |
| Probes from Fluke Calibration |
5615, 5627, 5626, 5628, 5622 |
5640-44, 5610-65 |
| Calibration |
ISO 17025-accredited calibration provided |
| †Temperature ranges and accuracy may be limited by the sensor you use. |
Includes: 1502A, 1504 Tweener Thermometer Readouts
| Model Name |
Description |
| 1502A |
Tweener PRT Readout
|
| 1502A-2506 |
Tweener PRT Readout, with IEEE-488
|
| 1504 |
Tweener Thermistor Readout
|
| 1504-2506 |
Tweener Thermistor Readout, with IEEE-488
|
| 9934-S |
LogWare, Single Channel, Single User
|
| 9934-M |
LogWare, Single Channel, Multi-User
|
Accessories: 1502A, 1504 Tweener Thermometer Readouts & common to all models
| Accessory |
Description |
| 9301 |
Carrying Case, fits Tweener and 12 in probe
|
| 2505 |
Spare Connector
|
| 2508 |
Serial Cable Kit
|
| 1929-2 |
System Verification, PRT with Readout, Accredited.
Choose two temperature points, extra points at additional cost. Available temperature points are –197 °C, -80 °C , –39 °C, 0.01°C, 30 °C, 157 °C, 232 °C, 300 °C, 420 °C, 500 °C, 660 °C.
|
| 1929-5 |
System Verification, Thermistor with Readout, Accredited.
Choose two temperature points; extra points at additional cost. Available temperature points are -30 °C, -20 °C, -10 °C, 0 °C, 10 °C, 20 °C, 30 °C, 40 °C, 50 °C, 60 °C, 70 °C, 80 °C, 90 °C, 100 °C.
|
| 1930 |
System Calibration, PRT with Readout, Accredited.
Choose PRT temperature range for the calibration. Available temperature ranges are –200 °C to 500 °C, –200 °C to 420 °C, –80 °C to 420 °C, –40 °C to 420 °C, –40 °C to 232 °C, 0 °C to 420 °C.
|
| 1935 |
System Calibration, Thermistor with Readout, NVLAP-accredited
Choose thermistor temperature range for the calibration. Available temperature ranges are 100 °C span (6 points over span), 60 °C span (7 points over span), 100 °C span (11 points over span).
|