Product overview: 9210 Mini Triple Point of Water Maintenance Apparatus

The triple point of water (0.01 °C) is one of the most important temperatures on the ITS-90. Unfortunately, realizing and maintaining triple point of water cells hasn’t always been convenient or cost-effective.

Because ITS-90 calibrations require frequent measurements at the triple point of water, and because the triple point of water is often used as a statistical check against the drift of a temperature standard, it is important to be able to realize and maintain well-constructed triple point of water cells easily.

The Fluke Calibration 9210 TPW Maintenance Apparatus provides built-in programming for the simple supercool-and-shake realization and maintenance of our 5901B Mini TPW Cell. Simply insert the cell, enter the “freeze" mode through the front-panel buttons, have your morning cup of coffee, and when the 9210 audibly alerts you, remove the Mini TPW Cell and give it a shake to initiate freezing a portion of the water. Re-insert the cell, change the program mode to “maintain," and you’ve got 0.01 °C for the rest of the day with uncertainty of only ±0.0005 °C.

Precision-machined thermal blocks can also be used to take advantage of the excellent stability and uniformity of the 9210 for performing comparison calibrations. Multi-hole and custom blocks are available with 178 mm (7 in) depths.

Key Features

  • Best value triple point of water solution.
  • Easy preprogrammed settings for TPW realization (5901B).
  • uncertainty of only ±0.0005 °C.
  • Dual function drywell capabilities.

Specifications: 9210 Mini Triple Point of Water Maintenance Apparatus

Specifications
Temperature Range –10 °C to 125 °C
Ambient Operating Range 5 °C to 45 °C
Stability ±0.02 °C
Vertical Gradient ±0.05 °C over 100 mm at 0 °C
Plateau Duration 6–10 hours, typical
Resolution 0.01 ° (0.001 ° in program mode)
Display Scale °C or °F, switchable
Immersion Depth 171 mm (6.75 in) in optional comparison block
Stabilization Time 15 minutes nominal
Preheat Wells 3 wells (for 3.18, 6.35, or 7.01 mm probes [0.125, 0.25, 0.276 in])
Fault Protection Adjustable software cutout using control probe; separate circuit thermocouple cutout for maximum instrument temperature
Display Accuracy ±0.25 °C
Comparison Block Three multi-hole blocks, blanks, and custom blocks available
Well-to-Well Gradient (in comparison block) ±0.02 °C
 
Heating Time Ambient to 100 °C: 45 min.
Cooling Time Ambient to –5 °C: 25 min.
Comm. RS-232 included
Power Requirements
 
115 VAC (±10 %), 60 Hz, 1.5 A, or
230 VAC (±10 %), 50 Hz, 0.75 A, 170 W
Exterior Dimensions (HxWxD) 489 x 222 x 260 mm (19.25 x 8.75 x 10.25 in)  
Weight 7 kg (15.5 lb.) with block

Accessories: 9210 Mini Triple Point of Water Maintenance Apparatus

Calibration inserts (4)

  • 3110-1 | Comparison Insert, Blank
  • 3110-2 | Comparison Insert A, holes at 1.6 mm
  • 3110-3 | Comparison Insert B, 2 holes at 4.76 mm (3/16 in)
  • 3110-4 | Comparison Insert C

Accessories: 9210 Mini Triple Point of Water Maintenance Apparatus

Calibration inserts (4)

  • 3110-1 | Comparison Insert, Blank
  • 3110-2 | Comparison Insert A, holes at 1.6 mm
  • 3110-3 | Comparison Insert B, 2 holes at 4.76 mm (3/16 in)
  • 3110-4 | Comparison Insert C

Product overview: 9210 Mini Triple Point of Water Maintenance Apparatus

The triple point of water (0.01 °C) is one of the most important temperatures on the ITS-90. Unfortunately, realizing and maintaining triple point of water cells hasn’t always been convenient or cost-effective.

Because ITS-90 calibrations require frequent measurements at the triple point of water, and because the triple point of water is often used as a statistical check against the drift of a temperature standard, it is important to be able to realize and maintain well-constructed triple point of water cells easily.

The Fluke Calibration 9210 TPW Maintenance Apparatus provides built-in programming for the simple supercool-and-shake realization and maintenance of our 5901B Mini TPW Cell. Simply insert the cell, enter the “freeze" mode through the front-panel buttons, have your morning cup of coffee, and when the 9210 audibly alerts you, remove the Mini TPW Cell and give it a shake to initiate freezing a portion of the water. Re-insert the cell, change the program mode to “maintain," and you’ve got 0.01 °C for the rest of the day with uncertainty of only ±0.0005 °C.

Precision-machined thermal blocks can also be used to take advantage of the excellent stability and uniformity of the 9210 for performing comparison calibrations. Multi-hole and custom blocks are available with 178 mm (7 in) depths.

Key Features

  • Best value triple point of water solution.
  • Easy preprogrammed settings for TPW realization (5901B).
  • uncertainty of only ±0.0005 °C.
  • Dual function drywell capabilities.

Specifications: 9210 Mini Triple Point of Water Maintenance Apparatus

Specifications
Temperature Range –10 °C to 125 °C
Ambient Operating Range 5 °C to 45 °C
Stability ±0.02 °C
Vertical Gradient ±0.05 °C over 100 mm at 0 °C
Plateau Duration 6–10 hours, typical
Resolution 0.01 ° (0.001 ° in program mode)
Display Scale °C or °F, switchable
Immersion Depth 171 mm (6.75 in) in optional comparison block
Stabilization Time 15 minutes nominal
Preheat Wells 3 wells (for 3.18, 6.35, or 7.01 mm probes [0.125, 0.25, 0.276 in])
Fault Protection Adjustable software cutout using control probe; separate circuit thermocouple cutout for maximum instrument temperature
Display Accuracy ±0.25 °C
Comparison Block Three multi-hole blocks, blanks, and custom blocks available
Well-to-Well Gradient (in comparison block) ±0.02 °C
 
Heating Time Ambient to 100 °C: 45 min.
Cooling Time Ambient to –5 °C: 25 min.
Comm. RS-232 included
Power Requirements
 
115 VAC (±10 %), 60 Hz, 1.5 A, or
230 VAC (±10 %), 50 Hz, 0.75 A, 170 W
Exterior Dimensions (HxWxD) 489 x 222 x 260 mm (19.25 x 8.75 x 10.25 in)  
Weight 7 kg (15.5 lb.) with block

Accessories: 9210 Mini Triple Point of Water Maintenance Apparatus

Calibration inserts (4)

  • 3110-1 | Comparison Insert, Blank
  • 3110-2 | Comparison Insert A, holes at 1.6 mm
  • 3110-3 | Comparison Insert B, 2 holes at 4.76 mm (3/16 in)
  • 3110-4 | Comparison Insert C

Accessories: 9210 Mini Triple Point of Water Maintenance Apparatus

Calibration inserts (4)

  • 3110-1 | Comparison Insert, Blank
  • 3110-2 | Comparison Insert A, holes at 1.6 mm
  • 3110-3 | Comparison Insert B, 2 holes at 4.76 mm (3/16 in)
  • 3110-4 | Comparison Insert C
seller

Sellers

Connect your real buyer on Tools Bangaldesh where visit the maximum customer for Tools In Bangladesh.

e-marketplace

e-Marketplace

Tools Bangladesh is a Trustworthy e-Marketplace in Bangladesh. Connect buyer and seller on the trade fair.

growth

Buyers

Get the reliable and authentic Tools at the best price in Bangladesh with on time delivery entire Bangladesh.