Specifications |
DC Volts range: |
1000 mV, 10 V, 100 V, 1500 V |
DC Volts resolution: |
0.1 mV in 1000 mV range |
DC Volts accuracy: |
±(0.1 % rdg + 5 dgt) |
DC Volts input impedance: |
10 MO |
DC Volts CMRR: |
>120 dB up to 1500 V dc |
DC Volts NMRR: |
>60 dB at 50 or 60 Hz |
DC Volts OL protection: |
1500 V dc or 1000 V ac rms |
DC Volts transient protection: |
12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V/1500V dc product. This product should not be used in installations |
AC Volts True-rms range: |
1000 mV, 10 V, 100 V, 1000 V |
AC Volts True-rms resolution: |
0.1 mV in 1000 mV range |
AC Volts True-rms accuracy: |
1000 mV (45 Hz to 400 Hz) ± (1.2 % rdg + 10 dgt) |
AC Volts True-rms accuracy: |
10 V, 100 V (45 Hz to 500 Hz) ± (1.2 % rdg + 10 dgt) |
AC Volts True-rms accuracy: |
10 V, 100 V (500 Hz to 2 kHz) ± (2.0 % rdg + 10 dgt) |
AC Volts True-rms accuracy: |
1000 V (45 Hz to 1 kHz) ± (2.0 % rdg + 10 dgt) |
AC Volts True-rms input impedance: |
10 MO |
AC Volts True-rms conversion type: |
True-rms, AC coupled 5 % to 100 % of range |
AC Volts True-rms crest factor: |
= 3 |
AC Volts True-rms OL protection: |
1500 V dc or 1000 V ac rms |
Transient protection: |
12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV |
DC Current range: |
100 µA, 1000 µA, 10mA, 100mA, 400mA, 2A (Auto/Manual ranging) |
DC Current resolution: |
0.01µA in 100 µA range |
DC Current accuracy: |
100 µA range ± (0.5% rdg + 10 dgts) |
DC Current accuracy: |
1000 µA to 400 mA ranges ± (0.5% rdg + 5 dgts) |
DC Current accuracy: |
2 A range ± (1.5% rdg + 10 dgts) |
DC Current input protection: |
2 A/1500 V fast blow ceramic fuse 8×65 mm on A input , FP700 |