Model: Fluke RaySafe i3 Real-time Dose Monitoring System
Fluke RaySafe i3 Real-time Dose Monitoring System is an active dosimetry system that provides real-time insights about radiation exposure.
The RaySafe i3 is an active dosimetry system that provides real-time insights about radiation exposure, helping medical staff and physicians evaluate and directly adjust their behaviors and more effectively use all the radiation reduction solutions provided in the room.
Fluke RaySafe i3 does not only provide the best result the value of this product revel in the workplace. Buy this product from Tools Bangladesh.
Key Features: RaySafe i3 Real-time Dose Monitoring System
Replaceable battery prolonged life cycle
The new Real-time Dosimeter has a replaceable battery, which means that longevity depends solely on wear and tear.
Better immunity to interference
RaySafe i2 dosimeters are sensitive to certain cell phone signals. The new Real-time Dosimeter is greatly improved in this regard no interference has been observed during heavy testing.
Automatic sleep mode
Only active dosimeters will populate the screen, regardless of where the inactive units are stored.
Enhanced measurement performance
Wider angular response means that radiation coming from below and from the sides is measured in a predictable fashion. Lowered dose rate threshold results in improved response when used with the latest low dose X-ray machines.
Weight
34 g (1.20 ounces)
Dimensions
40x58 x17 mm (1.6 x2.3 x 0.7 inch)
Operational quantity
H p (10)
Energy Dependence
<25% (N-series, 40 - 150kV)
Temperature Dependence
- <5%(18 °C 26 °C)
- <25% (15 °C to 18 °C, 26 °C to 35 °C)
Response Time
- <1 s, above 100 Sv/h
- <5 s, below 100 Sv/h
Dose Rate Uncertainty
(continuous radiation)
- 10% or 10Sv/h (40 Sv/h 150 mSv/h)
- 20% (150 mSv/h 300 mSv/h)
- 40% (300 mSv/h 500 mSv/h)
- The measured dose rate is monotonically increasing up to 1 Sv/h.
Dose Reproducibility
10% or 1 Sv
Maximum Lifetime Dose
10 Sv
Battery
°CR2450 (replaceable, 1 2 years lifetime depending on usage)
°Communication
Radio communication to real-time display, carrier frequency depending on region. USB port for connection to PC
Dimensions
300 x 250 x 60 mm (11.8 x 9.8 x 2.4 inch)
Display
10.4" touch screen
Storage
Dose rate by second and accumulated dose by hour for connected dosimeters. For 50 dosimeters the memory size allows storage of up to 5 years of accumulated dose and dose rate for the last 250 hours of exposure each.
Interfaces
Ethernet connection for Dose Manager USB connection for synchronizing data to USB memory stick
Power
12 V DC, <1.5 A External power supply included
Operating System
Windows XP, Vista, 7, 8 or 10
System Memory
- At least 1 GB (Dose Viewer)
- At least 2 GB (Dose Manager)
USB °Connection
1 USB 2.0
Hard Drive
At least 15 GB available space (Dose Manager)
Instrument specifications are subject to purchased configuration. All specifications may change without notice.
Product is not available in every country. °Check with your local representative for further information.
- Find in the resources file.